10
INSTALLATION INSTRUCTIONS
(CONTINUED)
Installing Air Inlet Filter
Screw supplied air inlet filter into inlet port of cast iron pump
as indicated in Figure 6.
Lubrication
This unit contains no oil.
Before operating compressor, fill
to the center of the sight gauge (see Figure 6).
Using any other type of oil may
shorten pump life and damage
valves.
Recommended Oil (2 Options)
Single viscosity SAE 30 ISO100 nondetergent
compressor oil.
10W30 synthetic oil such as Mobil 1
®
.
Oil Capacity
Approximately 18 ounces
Fill the pump with oil to the center of the sight gauge
using oil fill opening (see Figure 6).
Do NOT fill the
pump through the breather cap opening as this may
cause oil to leak and spray out during operation.
NOTE:
Some residual oil may still be in the pump from
factory testing leaving a thin coat on the sight gauge;
however, there is not enough oil to operate the unit.