14
8.8
Feed trip cam lever
The
Feed Trip Cam Lever
(A, Figure 8-6) is located
behind
Manual Fine Feed Handwheel
(B). It engages the
overload clutch on pinion shaft when positioned to the
left.
The
Feed Trip Cam Lever
stays engaged until
Quill Stop
(G, Figure 8-8) contacts
Micrometer Adjusting Nut
(F,
Figure 8-8) forcing it to drop out automatically, or until it
is released manually by pushing lever to the right.
Figure 8-6
8.9
Spindle speed control
While machine is running, turn speed control handwheel
(N, Figure 8-9) until desired speed shows on front plate.
Do not attempt to change spindle
speed unless motor is running.
8.10
Feed direction control
The
Feed Direction Control
(C, Figure 8-7) determines
whether power feed will move up, down, or not move at
all. The position of knob depends upon direction of
spindle rotation (see
sect. 8.2,
Motor Direction Switch).
Position of the control may be changed with the system
stopped or running. If the control does not engage easily,
move fine feed handwheel (B, Figure 8-7) back and forth
to aid engagement.
If spindle is rotating clockwise,
in
is downfeed;
out
is
upfeed. If spindle rotation is counterclockwise,
out
is
downfeed;
in
is upfeed. Neutral position is between
in
and
out
position.
It is recommended that Feed
Direction Control be left in neutral
position when not in use.
Figure 8-7
8.11
Coarse feed handle
The
Coarse Feed Handle
(D, Figure 8-8) is used for non-
precision drilling operations and for moving quill to a
specific depth. A return spring will retract spindle once
handle is released.
8.12
Quill lock handle
Rotate
Quill Lock Handle
(E, Figure 8-8) clockwise to lock
quill in desired position. Rotate handle counterclockwise
to release.
Figure 8-8
8.13
Depth scale and stop
Refer to Figure 8-8:
The
Depth Scale and Stop
are used in drilling operations
to set depth of drilled hole. The scale consists of a
Micrometer Adjusting Nut
(F),
Quill Stop
(G),
Quill Stop
Screw
(H), and
Scale
(J).
The
Micrometer Adjusting Nut
(F) provides a positive stop
for quill travel. Push button (F
1
) and slide nut to general
position, then rotate nut to specific depth setting.
Graduations on micrometer nut are in 0.001-inch
increments.
Summary of Contents for JTM-1254RVS
Page 7: ...7 4 1 Machine dimensions JTM 1254VS and JTM 1254RVS Figure 4 1 Installation Diagram...
Page 8: ...8 4 2 Overview and terminology JTM 1254VS and JTM 1254RVS Figure 4 2 Overview...
Page 19: ...19 Figure 9 6...
Page 22: ...22 12 1 1 JTM 1254VS Upper Head Assembly Exploded View...
Page 26: ...26 12 2 1 JTM 1254RVS R8 Upper Head Assembly Exploded View...
Page 30: ...30 12 3 1 JTM 1254VS Lower Head Assembly Exploded View...
Page 34: ...34 12 4 1 JTM 1254RVS R8 Lower Head Assembly Exploded View...
Page 38: ...38 12 5 1 JTM 1254VS Base Machine Exploded View...
Page 41: ...41 12 6 1 JTM 1254RVS R8 Base Machine Exploded View...
Page 52: ...52 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...