5
4.0
Specifications
Model number ............................................................................................................................................
JCDC-3
Stock numbers:
Complete kit ....................................................................................................................................... 717530K
Main unit only ....................................................................................................................................... 717530
Canister filter only ............................................................................................................................... 717530F
Motor and electricals:
Motor type ........................................................................ .totally enclosed fan cooled, induction, capacitor start
Horsepower ................................................................................................................................... 3 HP (2.2kW)
Phase
.......................................................................................................................................................... single
Voltage
................................................................................................................................................. 230V only
Cycle
............................................................................................................................................................ 60Hz
Listed FLA (full load amps) ........................................................................................................................... 13 A
Starting
amps
................................................................................................................................................ 39 A
Running
amps (no load) ............................................................................................................................ 12.5 A
Start
capacitor
......................................................................................................................... 500MFD, 125VAC
Run
capacitor
..................................................................................................................................... 40
μ
F 300V
On/off switch .............................................................. push-button, magnetic contactor with overload protection
Motor
speed ........................................................................................................................................ 3450 RPM
Power
cord
........................................................................................................................ 12AWG x 3C, 6ft.,SJT
Power
plug
.................................................................................................................
6-20P, 250V/20A installed
Recommended circuit and fuse/breaker size
1
............................................................................................. 20 A
Sound emission (at 9.84 ft./3m)
2
................................................................................................................ 76 dB
Remote
control
system
............................................
radio frequency (FCC approved); range up to 50 ft. (15 m)
RC transmitter battery ...................................................................................................................... 2 x AA, 1.5V
Timer
setting
................................................................................................................................ 2, 4, 6, 8 hours
Performance:
Inlet
diameter ................................................................................................................................ 8 in. (203 mm)
Inlet
adaptors,
number of ................................................................................................................................... 3
Inlet
adaptors,
diameter of ............................................................................................................. 4in. (100 mm)
Filter
efficiency
............................................................................................................. 99% of 2 micron particles
US method
EU method
Air Flow with filters installed ............................ 1240 CFM (2102 m
3
/hr) ........................ 1963 CFM (3327 m
3
/hr)
Air
Velocity
.............................................................
3542
FPM (18 m/s) ............................ 5609 FPM (28.5 m/s)
Static
pressure
loss (WC) ............................ 1.260 inH
2
O (32 mmH
2
O) ......................2.047 inH
2
O (52 mmH
2
O)
Maximum static pressure loss (WC) .......... 8.976 inH
2
O (228 mmH
2
O) ....................8.976 inH
2
O (228 mmH
2
O)
Impeller:
Impeller
diameter ........................................................................................................................ 15 in. (380 mm)
Impeller
type
.......................................................................................................................................... radial fin
Impeller
material
.......................................................................................................................................... steel
Canister filter:
Filter
type ........................................................................................................ cartridge and spunbond polyester
Canister filter diameter ........................................................................................................ 14-9/16 in. (370 mm)
Canister
filter
length
.............................................................................................................. 38-3/8 in. (975 mm)
Filter
surface area ................................................................................................................ 45.21 sq. ft. (4.2 m
2
)
Filter
efficiency
............................................................................................................. 99% of 2 micron particles
Cleaning
system
............................................................................................................
manual scraper rotation
Collection drum:
Capacity
.................................................................................................................................................... 66 gal.
Diameter
............................................................................................................................. 24-7/16 in. (620 mm)
Height
................................................................................................................................... 31-7/8 in. (810 mm)
Material
........................................................................................................................................................ steel
1
Subject to local/national electrical codes. Recommendation based upon dedicated circuit.
2
The specified values are emission levels and are not necessarily to be seen as safe operating levels. As workplace
conditions vary, this information is intended to allow the user to make a better estimation of the hazards and risks
involved only.