Summary of Contents for RX550i

Page 1: ...RX550i...

Page 2: ......

Page 3: ...before use We ask you to please read this manual carefully beforehand in order to familiarise yourself with this product and after reading please store this instructional manual for future reference...

Page 4: ...weather be sure ice has not formed in any part of the equipment While operating the pressure washer do not wear loose clothing jewellery or anything that may be caught in the engine Wear safety goggl...

Page 5: ...oses All hose connections must be properly sealed A thermal relief valve is provided to protect the pump from overheating if the spray gun is closed for an extended length of time or the nozzle become...

Page 6: ...procedures in this manual turn the pressure washer on and squeeze the trigger for activation It is very important to bleed the gun before using the pressure washer Squeeze the trigger to allow any ai...

Page 7: ...g in machine and turn on switch 9 Unlock trigger and use the pressure washer 1 Turn off the motor push switch to the off position 2 Unplug the unit from the power source 3 Turn off the water supply 4...

Page 8: ...be sprayed out from the spray nozzle in fan shapes fig 2 when cleaning the car or other vehicles Make sure that you have released the trigger and then turn the rear part of spray nozzle anti clockwise...

Page 9: ...y Wand at low pressure position fig 6 3 Trigger gun to spray detergent The hose reel handle turns down for use and up for storage To turn up the handle pull out and turn up fig 7 The Portable Pressure...

Page 10: ...nozzle backwards with water 5 Reconnect the wand to the gun Restart the pressure washer and depress the trigger on the spray gun If the nozzle is still partially blocked or plugged repeat above instr...

Page 11: ...nnect spark plug wire Prior to restarting thaw out any possible ice from the pressure washer hoses spray gun and wand Another method of reducing the risk of freeze damage is to drain your pressure was...

Page 12: ...lace Pump seals are worn out Clean and replace Water leaking from the pump Seals are worn out Check and replace The motor stops suddenly Thermal safety switch has tripped due to overheating Check that...

Page 13: ...7 L Min Max Flow Rate 8 7 1 Min Max Pressure Water Supply 0 4MPa 4bar Motor Capacity 2 5KW Power Supply Voltage 240V 50Hz LPA sound pressure 71dB A K 3 dB A LWA acoustic power 86 dB A Vibration Value...

Page 14: ...14 Portable Pressure Washer No Part 1 Pressure Cleaner 2 Water Supply Hose Not Included 3 Water Connection 4 Water Inlet 5 High Pressure Tube 6 Water Outlet 7 Spray Gun 8 Power Supply...