PN 115.04.7706 - INSTRUCTION MANUAL OF GPU JET-POWER DIESEL 90kVA - 115VAC, 400Hz / 28VDC, 2500A - PN 115.09.7701.
GPU JET-POWER DIESEL 90kVA – 115VAC, 400Hz / 28VDC, 2500A – PN 115.09.7090 16/40
SECTION 04 - INSPECTIONS, CHECKS AND LUBRICATION.
-
Make Diesel engine maintenance as indicated in the manufacturer's manual, with reference
to the sections listed below:
Daily maintenance or refueling:
• Lubricant Engine oil level;
• Coolant level engine - Verification and Maintenance (Add antifreeze if necessary);
• Cooling Fan - Inspect;
• Drive belt - Inspect;
• Fuel water separator - Drain
Maintenance every 400 hours or three months (whichever comes first):
• Lubricating oil - Change;
• Lubricating oil filter - Replace;
• Air filter restriction - Checking and maintenance. Replace if necessary;
• Battery - Inspect;
• Status of Diesel oil and water hoses - Inspect;
Maintenance every 800 hours or 6 months (whichever comes first):
• All the 400 hours review;
• Fuel Filters - Replace both.
Maintenance every 1200 hours or 1 year (whichever comes first):
• All of the review of 400 and 800 hours;
• Adjustment of head valves
Maintenance every 2000 hours or 2 years (whichever comes first):
• All the review 400, 800 and 1200 hours;
• Adjustment of head valves - Set
- Maintain the generator as shown in the manufacturer's manual. (Normally there is no need
maintenance. Only after 10,000 hours or 10 years, change the SKF bearing).
- Always keep stocked the diesel oil tank;
- Monthly complete the 12V battery level with distilled water (common battery);
- Weekly gauge tires (45 pounds). Do not use very high pressures in the tires, because the
GPU has no suspension and utilizes the low tire pressure to compensate for the imperfections
of the track without much twisting the chassis. In good tread can use up to 50 pounds.
- Never use solid tires, on pain of splitting its structure, losing the guarantee (only GPU's with
leaf springs is that it can be used).