Operating Instructions DIGITAL II Version 2.0
Start up
The delivered power plug which is equipped with protective earth contacts has to be connected with
the power plug port situated on the backside of the machine. Then put the other end of the cable
into an electrical power point 230 V / 50 Hz (120 V / 60 Hz). The unit will be switched on with the
toggle switch at the backside. The power of the rectifier is 15 V / 20 A.
Maintenance
Anode and cathode rods must be regularly cleaned with a Scotch sponge. Experience has shown that
this should be done every 6-8 weeks.
Short-circuit proof / fuse
The unit is short-circuit-proof if there will be short-circuit between cathode and anode.
The fuse is located on the backside of the machine, situated in main connection socket inside fuse
holder. Only micro fuse 4 A (slow blow), 115-250 V ~, 5* 20 mm must be used.
Attention
Make sure there is good ventilation in the work area.
Rinse water and used chemicals must be disposed of properly. Please refer to the legal regulations.
Please observe the instructions of the Safety Data Sheets (MSDS). Your chemical supplier provides
these.
The unit must be turned off after work necessarily!
The heater should never be operated unattended!
Chemicals
The required bath chemicals are available from us or from special producers. Please read the product
information of the manufacturer carefully and follow the instructions.