Service and maintenance 

 

Maintenance work may only be carried out when the 

axes are completely stopped.

 The axes must not be in the 

regulation and must first be disconnected from the 

power supply. 

 

The linear motor system must not be immersed or sprayed in 

liquids for cleaning. 

 

Basically, coarse contamination should be removed with a soft 

brush or with oil-free compressed air. 

 
 
 
 
 

10

 

Note 

 

This instruction manual contains copyright protected 

information. All rights are reserved. This document may not be 

in its entirety or partially copied, duplicated or translated 

without the prior consent of Jenny Science AG. 

 

Jenny Science AG grants no guarantee on, or will be held 

responsible for, any incidents resulting from false information. 

 

Information in this instruction manual is subject to change. 

 
 
 
 

Jenny Science AG 

Sandblatte 7a 

CH-6026 Rain, Schweiz 

 
 

Tel +41 (0) 41 455 44 55 

Fax +41 (0) 41 455 44 50 

 

www.jennyscience.ch 

[email protected] 

 
 

 

©   C o p y r i g h t   J e n n y   S c i e n c e   A G   2 0 2 0  

 
 
 
 

Summary of Contents for LINAX

Page 1: ...ber 2020 This documentation contains important safety and handling notes about LINAX linear motor axis ELAX electric slide and ROTAX rotary motor axis Improper handling of these motors and non observa...

Page 2: ...4 Environment Conditions 4 5 Handling with Linearmotor axis 5 5 1 Carriage 5 5 2 Measuring system 5 6 Mechanical assembly 6 6 1 Tightening torques 6 6 2 Flatness for mounting on ground plate 6 6 3 Fl...

Page 3: ...that objects made of steel or iron e g watches rings etc as well as technical devices e g computers credit cards hard disks etc which can be attracted influenced or destroyed by the magnetic field ar...

Page 4: ...em has been damaged during transport When unpacking the system take care not to damage sensitive parts such as cables connectors encoder and motor The commissioning of damaged products is prohibited 4...

Page 5: ...the linear motor on the cover plate 5 2 Measuring system Incorrect handling of the linear motor axes with a magnetic measuring system could erase parts of the magnetic measuring tape Prevent magnets e...

Page 6: ...ss Screw 70 6 2 Flatness for mounting on ground plate If the linear motor axes are mounted on a base plate this must have a flatness of 0 01mm Otherwise the linear motor axis may be distorted when scr...

Page 7: ...ontact surfaces have to be revised 7 Electrical connection A defective or incorrect power supply may result in irreparable damage to the machine An earthing cable must be connected to the system at al...

Page 8: ...er 8 1 Weight compensation Improper opening of the weight compensation is prohibited Make sure that during installation and maintenance work the pneumatic supply has been turned off and are not the su...

Page 9: ...nstruction manual contains copyright protected information All rights are reserved This document may not be in its entirety or partially copied duplicated or translated without the prior consent of Je...

Reviews: