INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Tools needed

Parts supplied

Gas pressure regulator

Burner grates

Burner bases and caps

Clamp brackets (2)

2

¹⁄₂

" (6.4 cm) clamping screws (2)

Foam tape seal

LP conversion kit - W10590568

Parts needed

Check local codes and consult gas supplier. Check existing gas 
supply and electrical supply. See “Electrical Requirements” and 
“Gas Supply Requirements” sections.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do 
not obstruct flow of combustion and ventilation air. 

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the underside of the 
cooktop burner box.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

The cooktop should be installed in a location away from 
strong draft areas, such as windows, doors and strong 
heating vents or fans.

All openings in the wall or floor where cooktop is to be 
installed must be sealed.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

Grounded electrical supply is required. See “Electrical 
Requirements” section.

Proper gas supply connection must be available. See “Gas 
Supply Requirements” section.

The gas and electric supply should be located as shown in 
“Gas and Electric Connection Locations” in the “Location 
Requirements” section so that they are accessible without 
requiring removal of the cooktop.

IMPORTANT: To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this cooktop must conform to the 
Manufactured Home Construction and Safety Standard, Title 24 
CFR, Part 3280 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD Part 280). When such 
standard is not applicable, use the Standard for Manufactured 
Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this cooktop must conform with the 
current standards CAN/CSA-A240-latest edition, or with local 
codes.

Product Dimensions

Gas and Electric Connection Locations

Tape measure

Flat-blade screwdriver

¹⁵⁄₁₆

" combination wrench

Pipe wrench

Channel lock pliers

Marker or pencil

Pipe-joint compound 
resistant to LP gas

Noncorrosive leak-detection 
solution

A. 30" (76.2 cm) on 30" (76.2 cm) models

36" (91.4 cm) on 36" (91.4 cm) models

B. 21" (53.3 cm) 

C. 3¼" (8.3 cm)

A. Gas pressure regulator (supplied) - arrow pointed 

toward cooktop

B. 3 prong grounding type outlet with correct polarity

C. 18" (45.7 cm) minimum
D. Gas shutoff valve

A

B

C

CL

C

A

B

D

Summary of Contents for W10588275B

Page 1: ...ation 18 SCHÉMAS DE CÂBLAGE 19 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided ...

Page 2: ...ier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions IMPORTANT Do not install a ventilation system that blows air downward toward this gas cooking appliance This type of ventilation system may caus...

Page 3: ...re minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The gas and electric supply should be located as shown in Gas and Electric Connection Locations in the Location Requirements section so that they are accessible without requiring removal of the cooktop IMPORTANT To avoid...

Page 4: ...ional Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this range be provided Electronic ignition systems operate within wide ...

Page 5: ...t use a flexible stainless steel tubing gas connector designed by CSA to connect the cooktop to the rigid gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the cooktop Rigid pipe connection The rigid pipe connection requires a combination of pipe ...

Page 6: ...e Gas Connection section 1 Using two or more people place the cooktop upside down on a covered surface 2 Remove foam strip from hardware package Remove backing from foam strip Apply foam strip with adhesive side to the countertop within 1 6 mm from the edge of the cutout front back and sides NOTE The foam strip helps keep the underside of the cooktop frame free from debris and helps the cooktop si...

Page 7: ...or use with LP gas to the larger thread ends of the flexible connector adapters see B and F in the following illustration 2 Attach 1 adapter to the gas pressure regulator and the other adapter to the gas shutoff valve Tighten both adapters 3 Use a combination wrench and channel lock pliers to attach the flexible connector to the adapters Check that connector is not kinked Complete Connection 1 Ope...

Page 8: ...heck the flame on HI for a blue color It should be clean and soft in character No yellow tip blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas 3 Repeat at LO position 4 Check the burner ON light for each burner 5 After verifying the proper burner operation turn the control knobs to OFF If burners do not light properly Tur...

Page 9: ...10 9 11 12 1 4 7 10 2 5 8 11 6 3 9 12 C C C C C C RF RF RF RF RF RF LF LF LF LF LF LF LR LR LR LR LR LR RR RR RR RR RR RR Electrodes Pilot Lights Receptacle 1 Plug 1 W G BK W 1 W 10 W 12 W W W W 9 W 8 W 11 W W BK 14 BK 15 BK 16 BK 17 BK 18 BK 18 BK BK BK BK BK BK BK BK BK BK BK N L1 N L1 N L1 N L1 Line wide blade Neutral wide blade 120 VAC 60 Hz 1 Phase 15 AMP Ground Round blade Ground Valve Switc...

Page 10: ...3 9 12 CF CF CF CF CF CF CR CR CR CR CR CR RF RF RF RF RF RF LF LF LF LF LF LF LR LR LR LR LR LR RR RR RR RR RR RR Electrodes Pilot Lights Receptacle 1 Plug 1 W G BK W 1 W 10 W 12 W W W W W 9 W 8 W 11 W W W 13 BK 14 BK 15 BK 16 BK 17 BK 19 BK 18 BK 18 BK BK BK BK BK BK BK BK BK BK BK BK BK N L1 N L1 N L1 N L1 N L1 Line wide blade Neutral wide blade 120 VAC 60 Hz 1 Phase 15 AMP Ground Round blade G...

Page 11: ...t AVERTISSEMENT Si les renseignements dans ce manuel ne sont pas exactement observés un incendie ou une explosion peut survenir causant des dommages au produit des blessures ou un décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d ...

Page 12: ...er les dimensions indiquées pour la cavité d installation entre les placards Ces dimensions tiennent compte des valeurs minimales des dégagements de séparation Une source d électricité avec liaison à la terre est nécessaire Voir la section Spécifications électriques Une source de gaz adéquate doit être disponible Voir la section Spécifications de l alimentation en gaz Veiller à placer les sources ...

Page 13: ... Si le placard comporte un tiroir on devra ménager une distance de séparation de 4 10 2 cm entre le plan de travail et le sommet du tiroir ou autre obstruction dans le placard inférieur Il pourra être nécessaire de réduire la profondeur du tiroir pour éviter une interférence avec le détendeur et le cordon d alimentation A 30 76 2 cm sur les modèles de 30 76 2 cm 36 91 4 cm sur les modèles de 36 91...

Page 14: ...la plus récente édition du code national en vigueur National Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent être effectués selon les instructions du fabricant Type de gaz Gaz naturel La conception de cette table de cuisson a été homologuée par Underwriters Laboratories UL cUL pour l alimentation au gaz naturel ou pour l alimentation au propane...

Page 15: ...cès au robinet d arrêt manuel Le robinet d arrêt manuel est prévu pour ouvrir ou fermer l alimentation en gaz de la table de cuisson Détendeur Le détendeur fourni avec cette table de cuisson doit être utilisé La pression d alimentation du détendeur doit être comme suit pour un fonctionnement correct Gaz naturel Pression minimum 6 15 2 cm colonne d eau Pression maximum 14 35 5 cm colonne d eau Gaz ...

Page 16: ... monter cette dernière dans le placard Voir la section Raccordement au gaz Table de cuisson sur four encastré sous comptoir IMPORTANT Ne pas utiliser de brides de fixation 1 Installer la table de cuisson dans l ouverture du plan de travail en inclinant une extrémité de la table de cuisson dans l ouverture puis en abaissant l autre extrémité dans l ouverture REMARQUE S assurer que le bord avant de ...

Page 17: ...letée la plus grosse des adaptateurs de raccord flexible voir B et F ci dessous 2 Fixer un raccord d adaptation sur le régulateur de pression du gaz et l autre raccord d adaptation sur le robinet d arrêt de la canalisation de gaz Serrer les deux raccords d adaptation 3 Utiliser une clé mixte de et une pince multiprise pour fixer le raccord flexible sur les raccords d adaptation Veiller à ne pas dé...

Page 18: ...e la flamme est bleue à la position HI Elle doit être propre et douce On ne doit pas observer de pointe jaune ni d effet de soufflage ou de séparation entre les flammes et le brûleur Il est normal d observer parfois des éclairs oranges ceci est dû à différents éléments dans l air ou le gaz 3 Répéter à la position LO bas 4 Vérifier le témoin de fonctionnement ON marche de chaque brûleur 5 Après avo...

Page 19: ...C AvD AvD AvD AvD AvD AvG AvG AvG AvG AvG ArG ArG ArG ArG ArG ArD ArD ArD ArD ArD Électrodes Veilleuse Contacteurs du robinet Réceptacle 1 Fiche 1 BL VE BL n 1 BL n 10 BL n 12 BL BL BL BL n 9 BL n 8 BL 11 BL BL N n 14 N n 15 N n 16 N n 17 N n 18 N n 18 N N N N N C AvD AvG ArG ArD Neu N N N N N N N Terre Phase Broche plate Neutre Broche plate 120 VCA 60 Hz monophasé 15 A Terre Broche ronde L1 Neu L...

Page 20: ...euse Contacteurs du robinet Réceptacle 1 Fiche 1 BL VE BL n 1 BL n 10 BL n 12 BL BL BL BL BL n 9 BL n 8 BL 11 BL BL BL n 13 N n 14 N n 15 N n 16 N n 17 N n 19 N n 18 N n 18 N N N N N N AvC ArC AvD AvG ArG ArD N N N N N N N 1 2 5 6 3 4 7 8 10 9 11 12 1 4 7 10 2 5 8 11 6 3 9 12 N Terre Phase Broche plate Neutre Broche plate 120 VCA 60 Hz monophasé 15 A Terre Broche ronde L1 Neu L1 Neu L1 Neu L1 Neu ...

Reviews: