background image

A – 3

16023510

©2004 Maytag Services

Installation Instructions 

(JXT5830AD*, JXT5836AD*)

Summary of Contents for JXT5830ADB

Page 1: ...es Vent Hoods This Base Manual covers general information Refer to individual Technical Sheet for information on specific models This manual includes but is not limited to the following Service This manual is to be used by qualified appliance technicians only Maytag does not assume any responsibility for property damage or personal injury for improper service procedures done by an unqualified pers...

Page 2: ... WARNING To avoid risk of severe personal injury or death disconnect power before working servicing on appliance to avoid electrical shock To locate an authorized servicer please consult your telephone book or the dealer from whom you purchased this product For further assistance please contact Customer Service Support Center CAIR Center Web Site Telephone Number WWW JENNAIR COM 1 800 688 1100 CAI...

Page 3: ...eFilter GreaseFiltgerCoverRemoval 13 Halogen Light Socket 13 Heat Lamp Socket Removal 13 LightPanelRemoval 14 ControlBoardRemoval 14 TouchPadRemoval 14 CapacitorRemoval 14 TransformerRemoval 15 BlowerMotorRemoval 15 Filter Spring Clip Removal 15 DisassemblyProceduresforModelsJXT8042ADS JXT8142ADS JXT58309AD JXT5836AD HalogenLightRemoval 16 GreaseFilter GreaseFiltgerCoverRemoval 16 Halogen Light So...

Page 4: ... has been completed 1 Check vent hood when service is complete After servicing make visual checks on electrical connection Inform consumer of the condition of vent hood before leaving 2 Adhere to all local regulations and codes when performing service Recognize this symbol as a safety precaution WARNING If the information in this manual is not followed exactly a fire or explosion may result causin...

Page 5: ...ites Ducted fans must always be vented to the outdoors Clean vent hood frequently Grease should not be allowed to accumulate on hood or filter When flaming foods under the hood turn the fan off The fan if operating may spread the flame Do not mix household cleaning products Chemical mixtures may interact with hazardous results Using the Vent Hood Do not allow anyone to climb stand or hang on the v...

Page 6: ...X T 9 1 3 6 C D P Brand A Amana C Magic Chef G Graffer Sattler H Hardwick J Jenn Air M Maytag N Norge U Universal Y Crosley Product Type A Accessory Cartridge C Cooktop Updraft Countertop D Downdraft Cooktop or Warming Drawer E Eyelevel Range G Grill L Range 20 M Range 36 P Drop In 24 Q Wall Oven 27 R Range Free Standing 30 S Slide In 30 T Range Hood V OTR W Wall Oven Y RV Range Z RV Top Fuel B Bu...

Page 7: ...ptacle cover screw does not ground the vent hood unless the cover screw is metal and not insulated and wall receptacle is grounded through the house wiring Consumer should have circuit checked by a qualified electrician to verify receptacle is properly grounded Model Identification Complete enclosed registration card and promptly return If registration card is missing For Jenn Air product call 1 8...

Page 8: ...rvices Range Description Vent Hood Description Touch Pad Control Pad Heat Lamps Halogen Lights Filters Filter Covers Blower Motor Touch Pad Control Pad Halogen Lights Filters Filter Covers in vent hood Blower Motor in vent hood ...

Page 9: ...ontrol board defective Touch pad or control panel defective Obstructions in blower motor Perform capacitor test Perform blower motor test Perform control board test Perform touch pad or control panel test Verify blower motor is free from obstructions and rotates freely Blower motor operates but cannot change fan speed Lights illuminate Capacitor shorted or defective Blower motor defective Touch pa...

Page 10: ...reaker isn t tripped Verify all connections are clean and tight wires are not broken Verify voltage is present If so perform control board test Perform touch pad or control panel test Heat lamp will not illuminate Heat lamp bulb defective No input power Circuit breaker tripped Loose wire connection or broken wire Touch pad or control panel defective Replace heat lamp bulb Verify 120 VAC is present...

Page 11: ...ead on negative terminal Reverse meter leads on capacitor terminals Check for a short by placing one lead on a terminal and the other to ground Meter reading should gradually increase capacitor charging Meter reading should gradually decrease capacitor discharging Infinity if shorted replace capacitor JXT9030CDP JXT9036CDP JXT9048CDP JXT9130CDP JXT9136CDP Capacitors 2 ea red wires input yellow wir...

Page 12: ...oltage by placing leads on screws in green connector black wire terminal input voltage and white wire terminal neutral 120 VAC JXT9030CDP JXT9036CDP JXT9048CDP JXT9130CDP JXT9136CDP Control Board Measure input voltage by placing meter leads on black white wire input voltage and white wire neutral 120 VAC JXT8030ADS JXT8036ADS JXT8042ADS JXT8136ADS JXT8142ADS JXT5830AD JXT5836AD Control Panel Measu...

Page 13: ...curing lamp reflector 7 Remove screws securing lamp socket and remove lamp socket 9 Reverse procedure to reinstall lamp socket Disassembly for models JXT9030CDP JXT9036CDP JXT9048CDP JXT9130CDP JXT9136CDP Halogen Light Removal 1 Turn off power to the light bulb 2 Twist light bulb counterclockwise from the socket NOTE A suction cup may be required for light bulb removal One may be obtained from a l...

Page 14: ...s securing light panel NOTE Some screws are located on top of light panel 4 Remove screws securing blower motor cover 5 Label and disconnect fan switch wires 6 Remove light socket see Light Socket Removal procedure 7 Angle the light panel slightly and gently pull down to remove from vent hood 8 Reverse procedure to reinstall light panel Control Board Removal 1 Disconnect power to vent hood 2 Remov...

Page 15: ...e to reinstall transformer Blower Motor Removal 1 Disconnect power to vent hood 2 Remove grease filters and covers see Grease Filter Grease Filter Cover Removal procedure 3 Remove screws securing blower motor covers 4 Remove blower wheel hub assembly 5 Loosen set screws and remove blower motor wheel 6 Remove screws securing blower motor to vent hood 7 Label and disconnect blower motor electrical c...

Page 16: ...over Removal procedure 4 Remove light panel see Light Panel Removal procedure 5 Remove screws securing light socket and remove light socket 6 Reverse procedure to reinstall light socket Grease Filter Grease Filter Cover Removal 1 Turn off power to the blower motors 2 Remove grease filter covers by using handles and pulling filter cover toward the rear of the vent hood 3 Pivot front of grease filte...

Page 17: ...t rod screws are removed the vent hood will lower 4 Remove screws securing cover to support rods 5 As the vent hood lowers label and disconnect electrical connections and ducting 6 Remove grease filters and covers see Grease Filter Grease Filter Cover Removal procedure 7 Remove screws securing all vent hood covers 8 Remove control panel see Control Panel Removal procedure 9 Disengage supports from...

Page 18: ...A 1 16023510 2004 Maytag Services Appendix A ...

Page 19: ... 2004 Maytag Services 16023510 A 2 Installation Instructions JXT5830AD JXT5836AD ...

Page 20: ...A 3 16023510 2004 Maytag Services Installation Instructions JXT5830AD JXT5836AD ...

Page 21: ... 2004 Maytag Services 16023510 A 4 Installation Instructions JXT8030ADS JXT8036ADS JXT8042ADS ...

Page 22: ...A 5 16023510 2004 Maytag Services Installation Instructions JXT8030ADS JXT8036ADS JXT8042ADS ...

Page 23: ... 2004 Maytag Services 16023510 A 6 Installation Instructions JXT8136ADS JXT8142ADS ...

Page 24: ...A 7 16023510 2004 Maytag Services Installation Instructions JXT8136ADS JXT8142ADS ...

Page 25: ... 2004 Maytag Services 16023510 A 8 Installation Instructions JXT9030CDP JXT9036CDP JXT9048CDP ...

Page 26: ...A 9 16023510 2004 Maytag Services Installation Instructions JXT9030CDP JXT9036CDP JXT9048CDP ...

Page 27: ... 2004 Maytag Services 16023510 A 10 Installation Instructions JXT9130CDP JXT9136CDP ...

Page 28: ...A 11 16023510 2004 Maytag Services Installation Instructions JXT9130CDP JXT9136CDP ...

Page 29: ... 2004 Maytag Services 16023510 B 1 Appendix B ...

Page 30: ...B 2 16023510 2004 Maytag Services Use Information JXT583 AD JXT803 ADS JXT8042ADS JXT8136ADS JXT8142ADS ...

Page 31: ... 2004 Maytag Services 16023510 B 3 Use Information JXT583 AD JXT803 ADS JXT8042ADS JXT8136ADS JXT8142ADS ...

Page 32: ...B 4 16023510 2004 Maytag Services Use Information JXT583 AD JXT803 ADS JXT8042ADS JXT8136ADS JXT8142ADS ...

Page 33: ... 2004 Maytag Services 16023510 B 5 Use Information JXT903 CDP JXT9048CDP JXT913 CDP ...

Page 34: ...B 6 16023510 2004 Maytag Services Care and Cleaning all ...

Reviews: