13
mm
4.
Secure power cord
■
Using the wire clamp provided, secure the wire as shown.
5.
Plug into a grounded 3 prong outlet
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Complete Installation
mm
.
.
1.
Install plastic transition
■
Align the plastic transition to the bottom of the charcoal filter
bracket and fasten it with the 2-2.9 x 6.5 mm screws.
6
"
(15.2 cm)
2.
Install duct
■
Slide the duct into place ensuring it is placed over the
exhaust of the hood and over the plastic transition.
■
Secure in place with the duct clamps.
NOTE:
Use of flexible duct is recommended.