IMPORTANT:
This appliance is intended to be used in
household and similar applications such as:
Staff kitchen areas in shops, of
fi
ce and other working
environments;
Farm houses and by clients in hotels, motels and other
residential type environments;
Bed and breakfast type environments;
Catering and similar non-retail applications.
NOTES:
For the double drawer to be
fl
ush with the front
of the base cabinets, remove any baseboards or
moldings from the rear of the opening. See “Product
Dimensions” and later in this section, “Opening
Dimensions.”
It is recommended that you do not install the double
drawer near an oven, radiator, or other heat source.
LOCATION REQUIREMENTS
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator drawers.
Failure to do so can result in death, explosion, or fire.
A
B
C
D
E
F
F
G
G
I
Recessed
receptacle
locations
Utility
opening
H
Opening and utility location dimensions
Opening width - A
24” (60.96 cm) min.
Opening depth - B
24” (60.96 cm) min.
Opening height - C
34
1
/
2
” (87.6 cm) min.
35” (88.9 cm) max.
Dimension - D
12
1
/
16
” (30.64 cm)
Dimension - E
21
3
/
4
” (55.24 cm)
Dimension - F
1
3
/
4
” (4.44 cm)
Dimension - G
3” (7.62 cm)
Dimension - H
4
1
/
2
” (11.43 cm)
Dimension - I
9
1
/
4
” (23.49 cm)
For flush installation, the power outlet can be installed
in adjacent cabinetry with a cutout on the power cord
side for routing of the power cord.
The power outlet can also be recessed on the back wall
behind the unit as per recommended receptacle
locations in the above illustration.
6
INSTALLATION REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts before starting
installation.
Read and follow the instructions provided with any tools
listed here.
TOOLS AND PARTS NEEDED:
Phillips screwdriver.
Cordless drill
1/8” Drill bit
Tape measure
Level
ADDITIONAL TOOLS NEEDED
(
CUSTOM OVERLAY
PANEL ONLY
)
:
Scissors
Pencil
Scribe
PARTS NEEDED
(
CUSTOM OVERLAY PANEL ONLY
)
:
Custom Overlay Drawer Panels — See “Custom Overlay
Drawer Panels.”
Hardware
PARTS NEEDED
(
CUSTOM OVERLAY PANEL ONLY
)
:
Hooks (8)
Screws (16)
Self-tap wood screws (4)
Do not install in a location where the temperature will
fall below 55 °F (13 °C). For best performance, do not
install the refrigerator drawers behind a cabinet door or
block the base grille.
OPENING DIMENSIONS:
Height dimensions are shown with the leveling legs
extended to the minimum height of 1/4” (6 mm) below
the refrigerator drawers.
NOTE:
When leveling legs are fully extended to 1” (25
mm) below the refrigerator drawers, add 3/4” (19 mm)
to the height dimensions. See “Product Dimensions.”
If the
fl
oor of the opening is not level with the kitchen
fl
oor, shim the opening to make it level with the
kitchen
fl
oor.
Summary of Contents for JUCFP242HL11
Page 2: ......