©2004 Maytag Appliances Company
16022821 Rev. 0
A – 3
Installation Instructions
2
f~~
1. Cut hole in cabinet to mount oven. Cutout in cabinet
should be level and straight.
klqbW
There are no provisions to level the unit after
it is installed. An oven that is not level could cause
poor baking results.
2. Install plywood floor as shown.
3. Remove oven door(s). See Oven Door Removal
procedure.
4. Attach unit to the cabinet with four No. 8 x 1
²
screws
supplied with unit inside of envelope containing these
instructions. Pre-drill holes in cabinet for attachment
screws using 1/8
²
drill. Oven mounting holes are
provided in side trim.
5. Install bottom trim.
6. Replace oven door(s). See Oven Door Replacement
procedure.
7. See instructions at right for electrical hook-up.
8. See Use and Care Manual for operating instructions.
f~ _ q m
f ~~
~ ~ K
Consult a qualified electrician or serviceman if the
grounding instructions are not completely understood, or
if doubt exists as whether the appliance is properly
grounded.
p
Interrupt the source of electricity to the unit when
attempting to repair or service the oven. Failure to do
this could result in a dangerous or even fatal shock.
fjmloq^kq J p^sb clo il`^i bib`qof`^i fkpmb`qloDp rpb
5(&200(1'(' 0,1,080
.: 5$7,1*
&,5&8,7 3527(&7,21
:,5( 6,=(
21 6(5,$/ 3/$7(
,1 $035(6
$:*
0 -
4.8
20
12
4.9 -
6.9
30
10
7.0 -
9.9
40
8
10.0 - 11.9
50
8
12.0 - 14.9
60
6
:$51,1*
b~ `
Unit to be properly circuit protected and wired according
to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be
accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on
each unit for power requirements.
The neutral of the lower unit is grounded to the frame
through the green or solid grounding wire. (The green
and the white wires are twisted together at the
termination of the conduit.) If used on new branch-circuit
installations (1996 NEC), mobile homes, recreational
vehicles, or in an area where local codes prohibit
grounding through the neutral conductor, untwist or
disconnect the green wire and connect the green wire to
ground in accordance with local code. Connect the white
neutral to the service neutral. Connect all wires to the
branch circuit with approved connectors. Use copper or
aluminum wire. If aluminum wire is used, use connectors
recognized for joining aluminum to copper.
The chart below recommends the minimum circuit
protection and wire size if the appliance is the only unit
on the circuit.
Remove lower screws
from hinge receptacle
plates. Align lower trim
and reinstall screws.
al klq fkpq^ii _lqqlj qofj rkqfi rkfq
fp ^qq^`eba ql qeb `^_fkbqK