3. Determine the type of regulator you have:

Style 1: The cap has a slot and “NAT” printed on it.

Remove access cap by using a flat-blade screwdriver or coin, 
turning the access cap counterclockwise.

The gas pressure regulator has 2 settings that are stamped 
on either side of the cap. Turn the cap and reinstall into 
regulator with the stamp “LP” visible from the outside of the 
regulator.

Style 2: The cap does not have a slot and requires a wrench 
to be removed.

Remove the access cap by using a wrench, turning the 
access cap counterclockwise.

Remove spring retainer from the cap by pushing against the 
flat side of the spring retainer. Look at the spring retainer to 
locate the “NAT” or “LP” position. Turn over the spring 
retainer so the “LP” is showing on the bottom. Snap the 
spring retainer back into the cap. Reinstall the cap onto the 
regulator.

4. Test the gas pressure regulator and gas supply line.

The regulator must be checked at a minimum 1" (2.5 cm) 
water column above the set pressure. The inlet pressure to 
the regulator should be as follows for operation and checking 
the regulator setting:

LP Gas:
Minimum pressure 10" (25.4 cm) W.C.P.
Supply pressure 14" (35.5 cm) W.C.P.

Gas Supply Pressure Testing

Line pressure testing above ½ psi gauge (14" WCP)

The cooktop and its individual shutoff valve must be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The cooktop must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than ½ psi (3.5 kPa).

5. If they are installed, remove the burner grates.
Use the following chart to match the correct gas orifice spud with 
the burner location and model being converted.
LP Gas Orifice Spud Chart

Burner Models

High Altitude Conversions

IMPORTANT: You must convert LP gas with LP gas High Altitude 
Kit Part Number W10593220 or Natural gas with Natural gas High 
Altitude Kit Part Number W10593221. If you need to convert LP 
gas to Natural gas high altitude or Natural gas to LP gas high 
altitude, you must convert the pressure regulator. For this, follow 
steps 1-3 of the necessary conversion.
LP Gas Orifice Spud Chart for High Altitude Conversion

See chart in the “LP Gas High Altitude Conversion Kit.”

Burner locations

30" (76.2 cm) Models

A. Access cap
B. Gasket

C. Gas pressure regulator

D. LP position

E. NAT position

A

B

C

D

E

Burner Rating

Stamp (A)

Size

5,000 BTU

66

0.66 mm

A. Size stamp

9,000 BTU

88

0.88 mm

12,000 BTU

102

1.02 mm

10,000 BTU

93

0.93 mm

Model No.

Right 
front

Right 
rear

Center/
center 
front

Center 
rear

Left 
front

Left 
rear

JGC7530BP

9,000 
BTU

5,000 
BTU

12,000 
BTU

N/A

12,000 
BTU

12,000 
BTU

JGC7636BP

9,000 
BTU

5,000 
BTU

12,000 
BTU

12,000 
BTU

12,000 
BTU

12,000 
BTU

JGC7530BS

9,000 
BTU

5,000 
BTU

10,000 
BTU

N/A

12,000 
BTU

10,000 
BTU

JGC7636BS

9,000 
BTU

5,000 
BTU

10,000 
BTU

10,000 
BTU

12,000 
BTU

10,000 
BTU

A. Left rear burner
B. Center burner

C. Right rear burner

D. Right front burner

E. Left front burner

A

A

A

B

C

D

E

Summary of Contents for JGC7530B SERIES

Page 1: ...lled or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages...

Page 2: ...upplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions In the State...

Page 3: ...version kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agenc...

Page 4: ... 14 WCP or lower The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa 5 If they are installed remove the burner grates Use the following chart to match the correct gas orifice spud with the burner location and model being converted...

Page 5: ...e you have completed converting all of the cooktop burners test the cooktop for leaks by brushing on an approved noncorrosive leak detection solution If bubbles appear a leak is indicated Correct any leaks found 12 Plug in cooktop or reconnect power 13 Adjust valve according to Flame Height Adjustment section A Left rear burner B Center rear burner C Right rear burner D Right front burner E Center...

Page 6: ...o the NAT is showing on the bottom Snap the spring retainer back into the cap Reinstall the cap onto the regulator 4 If they are installed remove the burner grates Use the following chart to match the correct gas orifice spud with the burner location and model being converted Natural Gas Orifice Spud Chart Burner Models A To cooktop B Shutoff valve closed position C Gas supply line A Access cap B ...

Page 7: ...ith correct Natural gas orifice spud See the Natural Gas Orifice Spud Chart 7 Place LP gas orifice spuds in plastic parts bag for future use and keep with package containing literature 8 Replace burner bases and burner caps IMPORTANT Be sure that the electrode aligns with the notch in the burner base The igniter electrode is ceramic and could break during installation of the burner base 9 Open shu...

Page 8: ...ver each burner can be adjusted To Adjust The flame can be adjusted using the adjustment screws underneath the control knob 1 Set the burner flame to LO 2 Remove the control knob 3 Hold knob stem with a pair of pliers Use a 0 2 0 mm flat blade screwdriver to turn the screw located within the shaft of the control knob stem until the flame is the proper size For LP gas conversion Completely tighten ...

Page 9: ... ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique Ne pas utiliser le téléphone se trouvant sur les lieux Appeler immédiatement le fournisseur de gaz à partir du téléphone d un voisin Suivre ses instructions À défaut...

Page 10: ...alifié d une agence de service en conformité avec les instructions du fabricant et les prescriptions de tous les codes en vigueur et des autorités juridictionnelles Si les présentes instructions ne sont pas rigoureusement respectées ceci peut provoquer un incendie une explosion ou la génération de monoxyde de carbone provoquant des dommages corporels ou matériels ou même la mort La responsabilité ...

Page 11: ...du circuit d alimentation en gaz Essai de pression de circuit à lb po 14 de colonne d eau ou moins La table de cuisson devra être isolée des canalisations d alimentation en gaz par la fermeture du robinet d arrêt manuel individuel durant un essai de pression des canalisations d alimentation en gaz à une pression égale ou inférieure à lb po 3 5 kPa 5 Enlever les grilles de brûleur si elles sont ins...

Page 12: ...bien alignée avec l encoche de la base du brûleur L électrode d allumage est en céramique et peut se briser durant l installation de la base du brûleur 10 Ouvrir le robinet d arrêt de la canalisation de gaz Le robinet est ouvert lorsque la manette est parallèle à la canalisation de gaz A Brûleur arrière gauche B Brûleur central C Brûleur arrière droit D Brûleur avant droit E Brûleur avant gauche A...

Page 13: ...tyle 2 Le chapeau ne comporte pas de rainure on doit utiliser une clé pour la dépose Utiliser une clé pour enlever le chapeau de l ouverture d accès faire tourner le chapeau dans le sens antihoraire Dégager le ressort de retenue du chapeau en poussant contre le côté plat du ressort de retenue Examiner le ressort de retenue pour identifier la position LP ou NAT Retourner le ressort de retenue pour ...

Page 14: ...gicleur du brûleur Remplacer le gicleur par un gicleur pour gaz naturel de taille correcte Voir le Tableau de sélection des gicleurs pour gaz naturel Puissance thermique Empreinte A Taille 6 000 BTU 110 1 10 mm A Empreinte de la taille 9 000 BTU 132 1 32 mm 12 000 BTU 155 1 55 mm 15 000 BTU 170 1 70 mm 18 000 BTU 193 1 93 mm Modèle n Avant droit Ar rière droit Central central avant Cen tral arrièr...

Page 15: ...sur le bouton de commande et le fait tourner jusqu à la position HI réglage élevé le système génère des étincelles pour l inflammation du gaz sur le brûleur Ces étincelles se produisent jusqu à l apparition d une flamme Contrôle du fonctionnement des brûleurs de la table de cuisson 1 Appuyer sur le bouton de commande et le tourner à la position HI réglage élevé La flamme doit apparaître sur le brû...

Page 16: ...r la vis dans le sens antihoraire pour augmenter la hauteur de flamme 4 Réinstaller le bouton de commande 5 Répéter les étapes 1 à 5 pour chaque brûleur 6 Contrôler la taille et la forme des flammes sur chaque brûleur Pour le réglage au débit thermique faible on doit observer des flammes stables bleues d environ 0 64 cm de haut 7 Compléter l étiquette de conversion fixer l étiquette sur le fond de...

Reviews: