Installation Clearances

IMPORTANT:

 If installing a range hood or microwave hood 

combination above the cooking surface, follow the range hood 

or microwave hood combination installation instructions for 

dimensional clearances above the cooktop surface.

Multi-Unit Dimensions

Units

Upper Cabinet 

Width (C)

Cutout 

Width (I)

One 15" (38.1 cm) unit

15"  

(38.1 cm)

14

3

/

8

(36.5 cm)

Two 15" (38.1 cm) units

30"  

(76.2 cm)

29

3

/

8

(74.6 cm)

Three 15" (38.1 cm) units

45"  

(114.3 cm)

44

7

/

16

(112.9 cm)

Four 15" (38.1 cm) units

60"  

(152.4 cm)

59

7

/

16

(151.0 cm)

30" (76.2 cm) cooktop and 

one 15" (38.1 cm) unit

45"  

(114.3 cm)

44

3

/

8

(112.7 cm)

30" (76.2 cm) cooktop and 

two 15" (38.1 cm) units

60"  

(152.4 cm)

59

7

/

16

(151.0 cm)

36" (91.4 cm) cooktop and 

one 15" (38.1 cm) unit

51"  

(129.5 cm)

50

3

/

8

(128.0 cm)

NOTE:

 After making the countertop cutout, some installations 

may require notching down the base cabinet side walls to clear 

the burner box. To avoid this modification, use a base cabinet 

with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the 

countertop to the top of the drawer (or other obstruction) in base 

cabinet is required. The drawer depth may need to be shortened 

to avoid interfering with the regulator and power cord.

Flush Installation Dimensions

All cooktops can be mounted with a frameless standard 

installation sitting on top of the countertop surface or flush 

with the top of the countertop. If the cooktop is to be mounted 

flush with the countertop, a 11/64”(4.3 mm)-deep recessed 

area surrounding the cooktop cutout must be provided with the 

following dimensions.

NOTE:

 This option is not recommended for countertops with a 

molded backsplash. Do not silicone seal in place.

Multi-Unit Flush Dimensions

Units

Recessed 

Area Width (D)

Cutout 

Width (C)

One 15" (38.1 cm) unit

15

1

/

8

"  

(38.4 cm)

14

3

/

8

(36.5 cm)

Two 15" (38.1 cm) units

30

1

/

8

"  

(76.5 cm)

29

3

/

8

(74.6 cm)

Three 15" (38.1 cm) units

45

1

/

8

(114.6 cm)

44

7

/

16

(112.9 cm)

Four 15" (38.1 cm) units

60

1

/

8

(152.7 cm)

59

7

/

16

(151.0 cm)

30" (76.2 cm) cooktop and 

one 15" (38.1 cm) unit

45

1

/

8

(114.6 cm)

44

3

/

8

(112.7 cm)

30" (76.2 cm) cooktop and 

two 15" (38.1 cm) units

60

1

/

8

(152.7 cm)

59

7

/

16

(151.0 cm)

36" (91.4 cm) cooktop and 

one 15" (38.1 cm) unit

51

1

/

8

(129.9 cm)

50

3

/

8

(128.0 cm)

IMPORTANT:

 If multiple units are installed side by side, the 

mounting bridge kit W11031680 is needed for proper installation. 

B

C

E

H

G

D

I

J

A

A

F

A.  18" (45.7 cm) minimum clearance upper cabinet to countertop
B. Cabinet
C.  See the Multi-Unit Dimensions table.
D.  13" (33 cm) maximum recommended upper cabinet depth
E.  6" (15.2 cm) minimum side wall clearance
F.  30" (76.2 cm) minimum clearance between top of cooktop platform 

and bottom of uncovered wood or metal cabinet (24" [61 cm] 

minimum clearance if bottom of wood or metal cabinet is covered by 

not less than 1/4" [0.6 cm] flame retardant millboard covered with not 

less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, 

or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)

G. 2

5

/

16

" (5.9 cm) minimum distance to rear combustible surface

H. 2

5

/

16

" (5.9 cm) minimum distance to front countertop edge

I.  See the Multi-Unit Dimensions table.
J.  Cutout depth - 20

3

/

8

" (51.8 cm)

D

C

A

B

E

F

E

Cooktop

Foam Strip

A.  Recessed area length - 21

3

/

16

" (53.8 cm)

B.  Cutout length - 20

3

/

8

" (51.8 cm)

C.  See the Multi-Unit Flush Dimensions table.
D.  See the Multi-Unit Flush Dimensions table.
E.  Recessed area depth 11/64" (4.3 mm)
F.  Recessed area radius 5/64" (2.0 mm) maximum

Summary of Contents for JGC3115GS

Page 1: ...the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING W11030506D IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installati...

Page 2: ...not always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do...

Page 3: ...where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded and polarized electrical supply is required See...

Page 4: ...is not recommended for countertops with a molded backsplash Do not silicone seal in place Multi Unit Flush Dimensions Units Recessed Area Width D Cutout Width C One 15 38 1 cm unit 151 8 38 4 cm 143...

Page 5: ...possible due to the normal operating nature of electronic gas cooktops The wiring diagram is provided with this cooktop It is located inside the cooktop burner box Gas Supply Requirements Observe all...

Page 6: ...to the regulator should be as follows for proper operation Natural Gas Minimum pressure 6 15 2 cm WCP Maximum pressure 14 35 5 cm WCP Propane Gas Minimum pressure 11 27 9 cm WCP Maximum pressure 14 35...

Page 7: ...top sit flat on uneven countertops Do not silicone seal in place Install Cooktop Install the pressure regulator to the cooktop before installing the cooktop See the Make Gas Connections section Multi...

Page 8: ...he following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shut off valve Tighten both adapters 3 Use a 15 16 2 4 cm combination wrench and channel l...

Page 9: ...hin 4 seconds The first time a surface burner is lit it may take longer than 4 seconds to light because of air in the gas line 2 Turn the control knob to HI and check for a blue colored flame It shoul...

Page 10: ...10 Notes...

Page 11: ...u un d c s Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE...

Page 12: ...tre install e dans un emplacement l cart des zones de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l empla...

Page 13: ...unit s de 15 38 1 cm 45 114 3 cm 447 16 112 9 cm Quatre unit s de 15 38 1 cm 60 152 4 cm 597 16 151 0 cm Table de cuisson 30 76 2 cm et une unit de 15 38 1 cm 45 114 3 cm 443 8 112 7 cm Table de cuis...

Page 14: ...e d un syst me d allumage lectronique qui ne fonctionnera pas en cas de branchement sur un circuit avec disjoncteur de fuite la terre Si les codes le permettent et si on utilise un conducteur distinc...

Page 15: ...cier inoxydable de 5 8 1 6 cm con u par CSA pour raccorder la table de cuisson la canalisation rigide d alimentation en gaz REMARQUE Dans le cas d installations multiples une seule vanne de fermeture...

Page 16: ...etirer l endos de la bande de mousse Pour les installations sur le comptoir Appliquer le c t adh sif de la bande de mousse sur le plan de travail 1 16 1 6 mm pr s des bords de l ouverture avant arri r...

Page 17: ...rd d adaptation sur le robinet d arr t de la canalisation de gaz Serrer les deux adaptateurs 3 Utiliser une cl mixte de 15 16 2 4 cm et une pince multiprise pour fixer le raccord flexible sur les racc...

Page 18: ...allumage initial du br leur de surface le d lai d allumage peut tre sup rieur 4 secondes du fait de la pr sence d air dans la canalisation de gaz 2 Tourner le bouton de commande la position HI lev e...

Page 19: ...19 Notes...

Page 20: ...W11030506D 2017 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 11 17...

Reviews: