background image

7

INSTALLATION INSTRUCTIONS

Prepare Cooktop for Installation

Write down the model and serial numbers before installing the 

cooktop. Both numbers are located on the center underside of 

the burner box.
Unpack the parts supplied with your cooktop. Do not unpack 

or remove the grate and burner base(s) from the carton until 

after the cooktop is installed to reduce the risk of scratching 

the cooktop.
The parts shipped with the cooktop depend on the model 

ordered. See the “Tools and Parts” section for a complete 

list of parts supplied with the cooktop.
Decide on the final location for the cooktop. Locate existing 

wiring to avoid drilling into or severing wiring during installation.
The pressure regulator and flexible stainless steel gas supply line 

can be assembled to the cooktop before or after the cooktop is 

installed. See the “Make Gas Connection” section.

1. 

Remove the foam strip from the hardware package. Remove 

the backing from the foam strip. 

For countertop installations: 

Apply the foam strip with the 

adhesive side to the countertop within 1/16" (1.6 mm) of the 

edge of the cutout, front, back, and sides.

For flush installations:

 Apply the foam strip with the 

adhesive side to the bottom of the cutout recessed area. 

Save the excess foam strip for use with the mounting 

bridge kit.

NOTE:

 The foam strip helps keep the underside of the 

cooktop frame free from debris and helps the cooktop 

sit flat on uneven countertops. Do not silicone seal in place.

Install Cooktop

Install the pressure regulator to the cooktop before installing the 

cooktop. See the “Make Gas Connections” section.

Multi-unit installation

For multi-unit installations, a mounting bridge kit is required. 

See the “Tools and Parts” section.

Cooktop over built-in oven

IMPORTANT:

 Clamping brackets should not be used.

1. 

Install the cooktop into the countertop cutout by tilting one 

end of the cooktop into the cutout, then lowering the other 

end into the cutout.

NOTE:

 Make sure that the front edge of the cooktop is parallel 

to the front edge of the countertop. If repositioning is needed, 

lift the entire cooktop up to avoid scratching the countertop.

Install cooktop into countertop

1. 

Remove the two hold-down screws located in each side of 

the cooktop burner box.

2. 

Attach the two hold-down brackets to the burner box.

3. 

Install the cooktop into the countertop cutout by tilting one 

end of the cooktop into the cutout, then lowering the other 

end into the cutout.

4. 

Start the hold-down screws into the hold-down brackets.

5. 

Center the cooktop in the opening and, using a wood block 

between the screw and the countertop, moderately tighten 

the screws to secure cooktop.

IMPORTANT:

 Do not tighten screws directly against the 

countertop.

WARNING

Excessive Weight Hazard

Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.

A
B
C
D

A. Countertop
B.  Foam strip
C. Cutout
D.  1/16" (1.6 mm)

A

B

C

E

D

A. Countertop
B.  Wood block
C.  Hold-down screw
D.  Hold-down bracket
E.  Burner box

Summary of Contents for JGC3115GS

Page 1: ...the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING W11030506D IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installati...

Page 2: ...not always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do...

Page 3: ...where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded and polarized electrical supply is required See...

Page 4: ...is not recommended for countertops with a molded backsplash Do not silicone seal in place Multi Unit Flush Dimensions Units Recessed Area Width D Cutout Width C One 15 38 1 cm unit 151 8 38 4 cm 143...

Page 5: ...possible due to the normal operating nature of electronic gas cooktops The wiring diagram is provided with this cooktop It is located inside the cooktop burner box Gas Supply Requirements Observe all...

Page 6: ...to the regulator should be as follows for proper operation Natural Gas Minimum pressure 6 15 2 cm WCP Maximum pressure 14 35 5 cm WCP Propane Gas Minimum pressure 11 27 9 cm WCP Maximum pressure 14 35...

Page 7: ...top sit flat on uneven countertops Do not silicone seal in place Install Cooktop Install the pressure regulator to the cooktop before installing the cooktop See the Make Gas Connections section Multi...

Page 8: ...he following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shut off valve Tighten both adapters 3 Use a 15 16 2 4 cm combination wrench and channel l...

Page 9: ...hin 4 seconds The first time a surface burner is lit it may take longer than 4 seconds to light because of air in the gas line 2 Turn the control knob to HI and check for a blue colored flame It shoul...

Page 10: ...10 Notes...

Page 11: ...u un d c s Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE...

Page 12: ...tre install e dans un emplacement l cart des zones de forts courants d air telles que fen tres portes et vents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l empla...

Page 13: ...unit s de 15 38 1 cm 45 114 3 cm 447 16 112 9 cm Quatre unit s de 15 38 1 cm 60 152 4 cm 597 16 151 0 cm Table de cuisson 30 76 2 cm et une unit de 15 38 1 cm 45 114 3 cm 443 8 112 7 cm Table de cuis...

Page 14: ...e d un syst me d allumage lectronique qui ne fonctionnera pas en cas de branchement sur un circuit avec disjoncteur de fuite la terre Si les codes le permettent et si on utilise un conducteur distinc...

Page 15: ...cier inoxydable de 5 8 1 6 cm con u par CSA pour raccorder la table de cuisson la canalisation rigide d alimentation en gaz REMARQUE Dans le cas d installations multiples une seule vanne de fermeture...

Page 16: ...etirer l endos de la bande de mousse Pour les installations sur le comptoir Appliquer le c t adh sif de la bande de mousse sur le plan de travail 1 16 1 6 mm pr s des bords de l ouverture avant arri r...

Page 17: ...rd d adaptation sur le robinet d arr t de la canalisation de gaz Serrer les deux adaptateurs 3 Utiliser une cl mixte de 15 16 2 4 cm et une pince multiprise pour fixer le raccord flexible sur les racc...

Page 18: ...allumage initial du br leur de surface le d lai d allumage peut tre sup rieur 4 secondes du fait de la pr sence d air dans la canalisation de gaz 2 Tourner le bouton de commande la position HI lev e...

Page 19: ...19 Notes...

Page 20: ...W11030506D 2017 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 11 17...