© 2006 Maytag Services
16026929
27
To avoid risk of electrical shock, personal injury or
death; disconnect power and gas to range before
servicing, unless testing requires power and/or gas.
Disassembly Procedures
Cooling Fan Replacement
1. Remove power from unit.
2. Remove range from installation position, see
"Removing and Replacing Range" procedure.
3. Remove back panel, see "Back Panel Removal"
procedure.
4. Label and disconnect wire terminals from cooling fan.
5. Remove screws securing fan to range chassis.
6. Reverse procedure to reinstall cooling fan.
Hidden Bake Element Replacement
(Select Models)
1. Remove power from unit.
2. Open oven door and remove rack(s).
3. Remove screws securing hidden bake element cover.
4. Remove hidden bake element cover by sliding cover
toward the rear of the oven cavity while lifting up on
front of cover.
5. Remove screws securing bake element to rear of
cavity wall.
6. Pull element forward to allow for labeling and
disconnection of wire terminals.
7. Remove element support clips.
8. Reverse procedure to reinstall bake element.
Bake Element Replacement (Select Models)
1. Remove power from unit.
2. Open oven door and remove rack(s).
3. Remove screws securing bake element to rear of
cavity wall.
4. Pull element forward to allow for labeling and
disconnection of wire terminals.
5. Remove element support clips.
6. Reverse procedure to reinstall bake element.
Broil Element Replacement
1. Remove power from unit.
2. Open oven door and remove racks.
3. Remove screws securing broil element to top and
rear of oven cavity.
4. Pull broil element forward to allow disconnection of
wiring from terminals.
5. Reverse procedure to reinstall broil element.
Downdraft Blower Motor Removal
(Select Models)
1. Remove power from unit.
2. Remove bottom access panel, see "Bottom Access
Panel Removal" procedure.
3. Disconnect ducting to allow for downdraft blower
motor removal.
4. Label and disconnect wire terminals.
5. Remove screws securing motor assembly.
6. Reverse procedure to reinstall downdraft blower
motor (select models).
Downdraft
blower motor
assembly
Convection Motor Removal
1. Remove power from unit.
2. Open oven door and remove rack(s).
3. Remove screws securing convection element and fan
cover (on rear wall of oven cavity).
4. Remove screw securing fan blade to fan motor shaft.
5. Remove screws securing fan motor to cavity wall.
6. Slide motor into oven cavity.
7. Label and disconnect wire terminals from motor.
8. Reverse procedure to reinstall convection motor.
Convection Element Replacement
1. Remove power from unit.
2. Open oven door and remove rack(s).
3. Remove screws securing convection element and fan
cover (on rear wall of oven cavity).
4. Remove screw securing convection element to rear
oven cavity wall.
5. Label and disconnect wire terminals from element.
6. Reverse procedure to reinstall convection element.
Summary of Contents for JDS8850BD
Page 38: ...A 8 16026929 2006 Maytag Services Installation Instructions ...
Page 39: ... 2006 Maytag Services 16026929 A 9 Installation Instructions ...
Page 40: ...A 10 16026929 2006 Maytag Services Installation Instructions ...
Page 41: ... 2006 Maytag Services 16026929 A 11 Installation Instructions ...
Page 42: ...A 12 16026929 2006 Maytag Services Installation Instructions ...
Page 43: ... 2006 Maytag Services 16026929 A 13 Installation Instructions ...
Page 44: ...A 14 16026929 2006 Maytag Services Installation Instructions ...
Page 67: ... 2006 Maytag Services 16026929 C 1 Appendix C ...