Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
© 2006 Maytag Services
16026929
23
"
Quick Test
"
Mode for EOC III
Follow the procedure below to perform the EOC III quick test. Once the control is in the quick test mode, any relay
may be activated in any sequence. The test mode will be exited after 10 minutes of inactivity (no pads pressed
within 10 minutes).
1. Press
the
Setup
pad, then press the right
ATM
pad.
2. Press
the
left
ATM
pad, then press and hold
Back
and
Enter
pads for 5 seconds to enter SERVICE menu options.
3. Press the right
ATM
pad to scroll to the TEST menu.
4. Press
the
left
ATM
pad to select TEST options.
5. Press
the
left
ATM
pad again to enter the
"
Quick Test
"
mode.
6. Press each of the following pads indicated in the table below.
7. Press
Cancel
or
Setup
pads to exit.
NOTE:
Press and hold the applicable pad to activate the associated response.
Release the applicable pad to deactivate the associated response.
The control automatically enters the engineering mode so visual feedback of relay operations is available on the
control display. Any time a load is activated, the cooling fan is activated. When the load is deactivated, the cooling
fan is also deactivated.
Display will indicate the following:
Pad Response
BAKE....................................................Bake relay activated.
BROIL ..................................................Broil relay activated.
CONVECT ...........................................Convection Bake relay activated.
OVEN LIGHT .......................................Oven light relay activated.
RAPID PREHEAT ................................Convection Fan (HIGH/LOW) activated.
WARMING ZONE ................................Warming Zone relay activated.
VENT (DOWNDRAFT) FAN ................Vent Fan relay activated.
CLEAN .................................................Motorized Door Lock relay activated.
SETUP .................................................1 Second Beep.
FAN ......................................................Downdraft Fan (HIGH/LOW) relay activated.
WARMING DRAWER ..........................Warming Drawer (HIGH/LOW) relay activated.
Summary of Contents for JDS8850BD
Page 38: ...A 8 16026929 2006 Maytag Services Installation Instructions ...
Page 39: ... 2006 Maytag Services 16026929 A 9 Installation Instructions ...
Page 40: ...A 10 16026929 2006 Maytag Services Installation Instructions ...
Page 41: ... 2006 Maytag Services 16026929 A 11 Installation Instructions ...
Page 42: ...A 12 16026929 2006 Maytag Services Installation Instructions ...
Page 43: ... 2006 Maytag Services 16026929 A 13 Installation Instructions ...
Page 44: ...A 14 16026929 2006 Maytag Services Installation Instructions ...
Page 67: ... 2006 Maytag Services 16026929 C 1 Appendix C ...