314
315
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________ __________________________________________________
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________ ____________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________ __
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________ _____________________________________________________
OPENING/CLEARANCE DIMENSIONS
FRONT VIEW
Floor
Wall
F
A
J
e
w
B
G
I
C
D
H
E
E
K
M
O
N
P
L
BACK VIEW
15" ICE MACHINES
JIM158XYR – 14
7
⁄
8
" x 33
3
⁄
4
" x 24
1
⁄
4
"
JIM158XYC – 14
7
⁄
8
" x 33
3
⁄
4
" x 24
3
⁄
4
"
MODEL #
JIM158XYR
JIM158XYC
in
cm
A
Width (min.)
15
38.1
Width without hinge side spacer option (min.)
15
38.1
Width with hinge side spacer option (min.)
15
3
⁄
4
*
40.0*
B
Width of outlet location
6
15.0
C
Outlet location – distance from side
1
2.5
D
Width of water connection location
3
1
⁄
2
8.9
E
Minimum width from hinged side of ice
machine to fixed wall – door open 90°
2
5.1
Minimum width from hinged side of ice machine
to fixed wall – door fully open 180° (JIM158XYR)
13
1
⁄
4
33.7
Minimum width from hinged side of ice machine
to fixed wall – door fully open 118° (JIM158XYC)
6
7
⁄
8
17.4
F
Height (min.)
34
86.4
G
Height of outlet location
8
20.3
H
Height of water connection location
9
22.9
I
Outlet location – distance from bottom
12
30.5
J
Depth of cabinet (min.)
24
61.0
K
Water line location – distance from side
2
3
⁄
4
7.0
L
Power supply – distance from side
3
5
⁄
8
9.3
M
Drain hose – distance from side
3
3
⁄
8
8.7
N
Power supply – distance from bottom
1
1
⁄
8
2.9
O
Drain hose – distance from bottom
7
1
⁄
4
18.6
P
Water line location – distance from bottom
14
3
⁄
8
36.7
e
Recommended electrical connection location
w
Recommended water connection location
* Install
3
⁄
4
" (1.9 cm) front hinge-side spacer flush with face of adjacent cabinet
and
3
⁄
4
" (1.9 cm) back hinge-side spacer 6" (15.2 cm) from back wall.
ELECTRICAL REQUIREMENTS
115 volt, 60 Hz, AC only, 15- or 20-amp fused, grounded circuit is required.
A dedicated circuit is recommended. Use an outlet that cannot be turned off
by a switch. Do not use an extension cord.
WATER PRESSURE REQUIREMENTS
A cold water supply with water pressure between 30 and 120 psi (207 and
827 kPa) is required to operate the ice maker. Call a licensed, qualified plumber with
any questions about the water pressure.
Reverse Osmosis Water Supply
IMPORTANT:
The use of a reverse osmosis system with this product is not
recommended. However if you do use reverse osmosis, follow these instructions.
Reverse osmosis systems will not work at all with auxillary drain pump 1901A.
IMPORTANT:
The pressure of the water coming out of a reverse osmosis system
going to the water inlet valve of the ice machine needs to be between 30 and 120
psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to the cold water supply, the
water pressure to the reverse osmosis system needs to be a minimum of
40 to 60 psi (276 to 414 kPa).
GRAVITY DRAIN SYSTEM REQUIREMENTS
The center of the drain should be 23" (58.4 cm) from the front of the door
and centered 7
3
⁄
8
" (18.6 cm) from left to right.
Floor
Wall
F
A
J
e
w
B
G
I
C
D
H
E
E
K
M
O
N
P
L
Floor
Back Wall
F
A
J
e
w
B
G
I
C
D
H
E
E
K
M
O
N
P
L
SIDE VIEW
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________ __________________________________________________
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________ ____________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________ __
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________ _____________________________________________________
NOTES
UNDER COUNTER