190
191
Cooktop Cutout
H*
J
A
F
B
C
D
G
H*
E
Vent Cutout
Cooktop Cutout
I
Cooktop Cutout
H*
J
A
F
B
C
D
G
H*
E
Vent Cutout
Cooktop Cutout
I
OPENING/CLEARANCE DIMENSIONS
GAS COOKTOP MODEL #
JGC7636B
JGC1536B
JGC7530B
JGC1530B
in
cm
in
cm
A
Width of vent cutout
39
7
⁄
16
100.2
39
7
⁄
16
100.2
B
Depth from cooktop cutout to
vent cutout (min.)
3
1
⁄
2
8.9
3
1
⁄
2
8.9
C
Depth of vent cutout
6
11
⁄
16
17.0
6
11
⁄
16
17.0
D
Depth from vent cutout to
wall (min.)
2
5.1
2
5.1
E
Depth of cooktop cutout
(recommended)
20
3
⁄
8
51.8
20
3
⁄
8
51.8
F
Width of cooktop cutout
(recommended)
35
3
⁄
8
89.9
29
3
⁄
8
74.6
G
Depth from cooktop cutout to
front of countertop
2
5
⁄
16
5.9
2
5
⁄
16
5.9
H*
Depth of cabinet (min.)
34
7
⁄
8
88.2
34
7
⁄
8
88.2
I
Width of cabinet (min.)
41
104.1
41
104.1
J
Height of recessed vent
29
15
⁄
16
76.0
29
15
⁄
16
76.0
*
IMPORTANT:
Cabinet and countertop depths are determined by the cooking appliances to
be used with this downdraft vent system.
SIDE VIEW
TOP VIEW
ELECTRICAL REQUIREMENTS
JXD7836B Accolade™ Downdraft Ventilation System
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
JGC7636B/JGC7530B Gas Cooktops
120 volt, 60 Hz, AC only, 15-amp fused, grounded circuit is required. A time-delay fuse
or dedicated circuit is recommended. Minimum power cord length is 46" (117.0 cm).
GAS REQUIREMENTS
Natural Gas
All gas cooktops are factory-set for use with natural gas.
LP Gas Conversion
Conversion must be done by a qualified service technician. To convert to LP gas, use
an LP gas conversion kit.
LOCATION REQUIREMENTS
JXD7836B Accolade™ Downdraft Ventilation System
Cabinet and countertop depth requirements may be deeper than 38" (96.5 cm). This
is determined by the cooking appliances being installed with this downdraft vent system.
JGC7636B/JGC7530B Gas Cooktops
• To ensure cooktop base clearance, cabinet side walls need to be wider than the cutout.
• If cabinet has a drawer, allow a 4" (10.2 cm) minimum clearance between
countertop and top of drawer. Drawer depth may need to be shortened to avoid
interfering with the regulator.
VENTING REQUIREMENTS
The vent is factory set for a 10" diameter (25.4 cm) vent system venting through the
wall or floor. Do not terminate the vent in an attic or other enclosed area.
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________ __________________________________________________
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________ ____________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________ __
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________ _____________________________________________________
COMBINATION INSTALLATION
JXD7836B 36" ACCOLADE
™
DOWNDRAFT VENTILATION SYSTEM &
JGC7636B, JGC1536B 36" GAS COOKTOPS OR
JGC7530B, JGC1530B 30" GAS COOKTOPS
JXD7836B – 40
3
⁄
4
" x 57
5
⁄
16
" x 10
3
⁄
8
"
JGC7636B – 36" x 5
1
⁄
4
" x 21"
JGC1536B – 36" x 4
3
⁄
16
" x 21"
JGC7530B – 30" x 5
1
⁄
4
" x 21"
JGC1530B – 30" x 4
3
⁄
16
" x 21"
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________ __________________________________________________
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________ ____________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________ __
____________________________________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________________________________________
_______________________________________________________________________________________________ _____________________________________________________
Cooktop Cutout
H*
J
A
F
B
C
D
G
H*
E
Vent Cutout
Cooktop Cutout
I
Cooktop Cutout
H*
J
A
F
B
C
D
G
H*
E
Vent Cutout
Cooktop Cutout
I
COMBINATION INSTALLATION
JXD7836B 36" ACCOLADE
™
DOWNDRAFT VENTILATION SYSTEM &
JEC3536B 36" ELECTRIC RADIANT COOKTOPS OR
JEC4536B 36" ELECTRIC RADIANT COOKTOP WITH ELECTRONIC TOUCH CONTROL
JXD7836BS – 40
3
⁄
4
" x 57
5
⁄
16
" x 10
3
⁄
8
"
JEC3536BS, JEC4536BS – 36
7
⁄
16
" x 5
5
⁄
16
" x 22
3
⁄
16
"
JEC3536BB, JEC4536BB – 36
5
⁄
16
" x 5
5
⁄
16
" x 21
11
⁄
16
"
OPENING/CLEARANCE DIMENSIONS
ELECTRIC COOKTOP MODEL #
JEC3536B
JEC4536B
in
cm
A
Width of vent cutout
39
7
⁄
16
100.2
B
Depth from cooktop cutout to vent cutout (min.)
3
1
⁄
2
8.9
C
Depth of vent cutout
6
11
⁄
16
17.0
D
Depth from vent cutout to wall (min.)
2
5.1
E
Depth of cooktop cutout (recommended)
20
1
⁄
2
52.0
F
Width of cooktop cutout (recommended)
35
1
⁄
2
90.2
G
Depth from cooktop cutout to front of countertop
2
5
⁄
8
6.7
H*
Depth of cabinet (min.)
35
5
⁄
16
89.7
I
Width of cabinet (min.)
41
104.1
J
Height of recessed vent
29
15
⁄
16
76.0
*
IMPORTANT:
Cabinet and countertop depths are determined by the cooking appliances to
be used with this downdraft vent system.
SIDE VIEW
TOP VIEW
ELECTRICAL REQUIREMENTS
JXD7836B Accolade™ Downdraft Ventilation System
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
JEC3536B/JEC4536B Electric Radiant Cooktops
A 3-wire or 4-wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply is
required on a separate, 40-amp circuit fused on both sides of the line. 48" (121.9
cm) of
1
⁄
2
" (1.3 cm) I.D. flexible cable is provided.
LOCATION REQUIREMENTS
JXD7836B Accolade™ Downdraft Ventilation System
Cabinet and countertop depth requirements may be deeper than 38" (96.5 cm). This
is determined by the cooking appliances being installed with this downdraft vent system.
JEC3536B/JEC4536B Electric Radiant Cooktops
• To ensure cooktop base clearance, cabinet side walls need to be wider than
the cutout.
• If cabinet has a drawer, allow a 5
1
⁄
2
" (14.0 cm) minimum clearance between
countertop and top of drawer.
VENTING REQUIREMENTS
The vent is factory set for a 10" diameter (25.4 cm) vent system venting through the
wall or floor. Do not terminate the vent in an attic or other enclosed area.
VENTILA
TION