9
QUICK DISCONNECT ASSEMBLY
1. Install the quick disconnect by pulling the spring ring
downward on the female connector; insert the female
connector and release the spring ring (A).
2. After spring ring is released, male and female quick
disconnect will be locked together. Double check by
slightly pulling the hose connector upward, if not properly
connected, hose will be detached. Do not use excess
pulling force; doing so may cause manifold and/or burner
valve to become misaligned.
3. Make sure all the connections are tightly secured by
spraying a soapy solution (refer to “Leak Testing”
section).