GAS HOOK-UP
Only the pressure regulator and hose assembly
supplied with the grill should be used. Any
replacement pressure regulator and hose assembly
must be specified by the grill manufacturer.
Total gas consumption (per hour) of 720-0101-NG
grill with all burners on “HI”:
Main burners
60,000 Btu/hr.
Rear burners
12,000 Btu/hr
Side burner
12,000 Btu/hr.
Total
84,000 Btu/hr.
The installation of this appliance must conform with
local codes or, in the absence of local codes, with
the national fuel gas code, ANSI Z223. 1.
GENERAL
Although all gas connections on the grill are leak
tested at the factory prior to shipment, a complete
gas tightness check must be performed at the
installation site due to possible mishandling in
shipment, or excessive pressure unknowingly being
applied to the unit. Periodically check the whole
system for leaks following the procedures listed
below. If the smell of gas is detected at anytime you
should immediately check the entire system for
leaks.
BEFORE TESTING
Make sure that all packing material is removed from
the grill including the burner tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING.
NEVER LEAK TEST WITH AN OPEN FLAME.
Make a soap solution of one part liquid detergent
and one part water. You will need a spray bottle,
brush, or rag to apply the solution to the fittings.
TO TEST
Make sure all control valves are in the “OFF”
position. Turn the gas supply on. Check all
connections from the natural gas regulator and
supply valve up to and including the connection to
the manifold pipe assembly (the pipe that goes to
the burners). Soap bubbles will appear where a
leak is present. If a leak is present, immediately turn
off the gas supply, tighten any leaking fittings, turn
gas on, and recheck. Should the gas continue to
leak from any or all of the fittings, turn off the gas
supply, and contact our customer service at 1-800-
913-8999.
Only those parts recommended by the
manufacturer should be used on the grill.
Substitution will void the warranty. Do not use the
grill until all connections have been checked and do
not leak.
Gas flow check:
Each grill burner is tested and adjusted at the
factory prior to shipment; however, variations in the
local gas supply may make it necessary to adjust
the burners. The flames of the burners should be
visually checked.
Flames should be blue and stable with no yellow
tips, excessive noise or lifting. If you have any
questions regarding flame stability, please call
customer service at 1-800-913-8999.
Check all gas supply fittings for leaks before each use.
It is handy to keep a spray bottle of soapy water near
the shut-off valve of the gas supply line. Spray all the
fittings. Bubbles indicate leaks.
LEAK TESTING
Locking Nut
Adjustment Bolt
8