Jenn-Air 36inch AND 42inch (91.4 CM AND 106.7 CM) ISLAND CANOPY RANGE... Use & Care Manual Download Page 12

12

RANGE HOOD USE

The range hood is designed to remove smoke, cooking vapors and 
odors from the cooktop area. For best results, start the hood 
before cooking and allow it to operate several minutes after the 
cooking is complete to clear all smoke and odors from the kitchen.
The range hood controls are located on the front side of the canopy.

Control Panel

The range hood controls are located on the front side of the canopy.

Display

Grease Filter Saturation Alarm

After 30 hours of fan function, the display will show “Clean 
Grease Filter” when the fan is active. When this icon shows in the 
display, the installed grease filters should be washed. See 
“Range Hood Care” section.

To reset the grease filter saturation alarm, press and hold the 
POWER INCREASE button for 5 seconds. The “Clean Grease 
Filter” icon will no longer be displayed.

Charcoal Filter Saturation Alarm

After 120 hours of fan function, the display will show “Replace 
Charcoal Filter” when the fan is active. When this icon shows in 
the display, the charcoal filters should be replaced. See “Range 
Hood Care” section.

To reset the charcoal filter saturation alarm, press and hold 
the POWER DECREASE button for 5 seconds. The “Replace 
Charcoal Filter” icon will no longer be displayed.

Audible Signal Activation and Deactivation

The audible signals can be activated or deactivated by pressing 
the “LIGHT” button for 5 seconds.

If the audible signal is activated, a tone will sound, and “Snd” 
symbol will appear in the display for 3 seconds.

If the audible signal is deactivated, the “Snd” symbol will 
appear on the display for 3 seconds.

Charcoal Filter (Recirculation Accessory) Inclusion 
and Exclusion

When the charcoal filter is in use (recirculating mode), press and 
hold the POWER DECREASE and POWER INCREASE buttons at 
the same time for 5 seconds. “Able” will appear in the display for 

 

3 seconds. 
If the charcoal filter is not used (vented mode), press and hold the 
POWER DECREASE and POWER INCREASE buttons at the 
same time for 5 seconds. “None” will appear in the display for 

 

3 seconds. 

When the charcoal filter has been excluded, the charcoal filter 
alarm is disabled.

The inclusion or exclusion of the charcoal filter must be 
selected while the lights and the fan motor are Off.

Heat Sensor

The control is equipped with a heat sensor that will turn on the 
blower to the highest speed if excessive heat occurs around the 
control area.

If the blower is On or Off, the blower will automatically set to 
the highest speed. “Auto” will appear in the display to 
indicate that the heat sensor has detected excessive heat.

When the blower is operating due to excessive heat detected 
by the heat sensor, the blower speed cannot be decreased.

When the temperature level on the hood drops to normal, the 
blower will return to its setting before the excessive heat was 
sensed.

Light

To operate the light:

1.

Press the Light button to turn the light on to high.

2.

Press the Light button again to turn the light to low.

3.

Press the Light button a third time to turn the light off.

Timer 

The timer can be set from 1 to 60 minutes. The default timer 
setting is 10 minutes.

To use the timer:

1.

Press the Timer button to enter the timer mode. After 
5 seconds the default time will be automatically selected.

2.

Press the POWER DECREASE and POWER INCREASE 
buttons while the display is flashing (5 seconds) to adjust to 
the desired time. Pressing the timer button again or waiting 

 

5 seconds after selecting the desired time will start the timer 
countdown.

3.

The timer can be canceled at any time by pressing the Timer 
button again. 

NOTE:

 During the timer setup, the Power Decrease and Power 

Increase buttons are dedicated to the timer. After the timer starts, 
the Power Decrease and Power Increase buttons can be used for 
other functions.

A. Louver holes (non-vented 

[recirculating] installations only)

B. Duct covers

C. Lamp housings

D. Canopy

E. Grease filters

F. Grease filter handles

G. Control panel

A. Power decrease
B. Power increase

C. Display
D. Light

E. Timer

A

B

C

D

E

F

G

A

B

C

D

E

Summary of Contents for 36inch AND 42inch (91.4 CM AND 106.7 CM) ISLAND CANOPY RANGE...

Page 1: ...bsite at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance...

Page 2: ...u ventilateur 28 ENTRETIEN DE LA HOTTE 29 Nettoyage 29 SCH MA DE C BLAGE 30 ASSISTANCE OU SERVICE 31 Au Canada 31 Accessoires 31 GARANTIE 32 RANGE HOOD SAFETY You can be killed or seriously injured if...

Page 3: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Page 4: ...with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should b...

Page 5: ...k draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper shoul...

Page 6: ...sed electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added...

Page 7: ...to a ceiling support structure capable of holding 80 lbs 36 6 kg Remove the template 4 Drill 4 4 8 mm pilot holes for mounting the upper horizontal support Complete Preparation 1 Determine the require...

Page 8: ...ighten to secure Connect Vent System 1 Install vent system 2 Push duct over the exhaust outlet Seal all connections with vent clamps 3 Use caulk to seal all openings Non Vented Recirculating Installat...

Page 9: ...hten strain relief screw 9 Install terminal box cover 10 Check that all light bulbs are secure in their sockets 11 Reconnect power A Knockout B Terminal box C Terminal box cover WARNING Electrical Sho...

Page 10: ...he frame to the ceiling and secure to the upper horizontal support with 2 3 5 x 6 5 mm screws 4 Place the long end of the plastic clips 2 into the bottom of the front lower duct cover 5 Install the lo...

Page 11: ...using 2 plastic clips Use one plastic clip on each side 8 Secure the lower duct cover to the range hood canopy using 4 4 2 x 8 mm screws Complete Installation 1 For non vented recirculating installati...

Page 12: ...and hold the POWER DECREASE and POWER INCREASE buttons at the same time for 5 seconds None will appear in the display for 3 seconds When the charcoal filter has been excluded the charcoal filter alar...

Page 13: ...detergent solution 3 Reinstall the filter by making sure the spring release handles are toward the front Insert metal grease filter into upper track 4 Pull the spring release handle down 5 Push up on...

Page 14: ...3 4 5 1 2 3 4 5 6 YL YL YL BU YL YL YL S4 P9 BK BU BR GY YL WH RD Motor Resistance Ohms Blue Red Blue Gray Blue Black Blue White Room Temp 18 14 3 9 8 21 6 Motor Specifications Power Supply Frequency...

Page 15: ...ance you can write to Jenn Air Appliances with any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a dayti...

Page 16: ...light bulbs batteries air or water filters preservation solutions etc 5 Conversion of products from natural gas or L P gas 6 Damage from accident misuse abuse fire floods acts of God or use with prod...

Page 17: ...re appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous sign...

Page 18: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Page 19: ...es sp cifi es sur la plaque signal tique de l appareil La plaque signal tique de l appareil est situ e derri re le filtre de gauche sur la paroi arri re de la hotte On doit toujours installer la hott...

Page 20: ...nch it avec un produit de calfeutrage La taille du conduit doit tre uniforme Installations dans une r gion climat froid Dans le circuit d vacuation on devrait installer un clapet anti reflux additionn...

Page 21: ...l 8501 East Pleasant Valley Road Cleveland OH 44131 5575 L appareil doit tre aliment par un circuit de 120 V CA seulement 60 Hz 15 amp res prot g par fusible Si le domicile poss de un c blage en alumi...

Page 22: ...des trous doit se faire dans une structure de soutien du plafond capable de soutenir une charge de 80 lb 36 6 kg Retirer le gabarit 4 Percer 4 avant trous de 4 8 mm pour le montage du support horizont...

Page 23: ...ncer le conduit sur la bouche d vacuation Utiliser des brides de conduit pour assurer l tanch it de toutes les connexions 3 Utiliser un calfeutrant pour assurer l tanch it au niveau de chaque ouvertur...

Page 24: ...Installer le couvercle du bo tier de connexion 10 V rifier que chaque ampoule est bien ins r e dans sa douille 11 Reconnecter la source de courant lectrique A Opercule arrachable B Bo tier de connexi...

Page 25: ...vis de 3 5 x 6 5 mm 4 Placer l extr mit longue des chevilles en plastique 2 au bas de la partie inf rieure avant du cache conduit 5 Installer la partie inf rieure du cache conduit avant l auvent de l...

Page 26: ...une cheville en plastique de chaque c t 8 Fixer la partie inf rieure du cache conduit l auvent de la hotte de cuisini re en utilisant 4 vis de 4 2 x 8 mm Achever l installation 1 Pour les installatio...

Page 27: ...Snd son appara t sur l affichage pendant 3 secondes Inclusion et exclusion du filtre charbon accessoire de recyclage Lorsque le filtre charbon est utilis mode recyclage appuyer sur les boutons POWER...

Page 28: ...de la minuterie commence 3 La minuterie peut tre annul e tout moment en appuyant de nouveau sur le bouton de la minuterie REMARQUE Pendant le r glage de la minuterie les boutons Power Decrease et Powe...

Page 29: ...e haut et rel cher la poign e pour l embo ter 6 R p ter les tapes 1 5 pour l autre filtre Filtres d installation sans d charge l ext rieur recyclage Le filtre charbon n est pas lavable Celui ci devrai...

Page 30: ...1 2 3 4 5 1 2 3 4 5 6 JA JA JA BU JA JA JA S4 P9 N BU MAR JA BL R R sistance du moteur ohms Bleu Rouge Bleu Gris Bleu Noir Bleu Blanc Temp amb 18 14 3 9 8 21 6 Caract ristiques du moteur Alimentation...

Page 31: ...techniciens de service d sign s par Jenn Air sont form s pour remplir la garantie des produits et fournir un service apr s la garantie partout au Canada Caract ristiques et sp cifications de notre gam...

Page 32: ...p trole liqu fi 6 Dommages caus s par accident m susage abus incendie inondations catastrophe naturelle ou l utilisation de produits non approuv s par Jenn Air 7 R parations aux pi ces ou syst mes dan...

Reviews: