Jenn-Air 32

3

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

WARNING: 

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING: 

■  

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer.

■  

Before servicing or cleaning the unit, switch power off at 
service panel and lock the service disconnecting means to 
prevent power from being switched on accidentally. When 
the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a tag, 
to the service panel.

■  

Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction.

■  

Do not operate any fan with a damaged cord or plug. 
Discard fan or return to an authorized service facility for 
examination and/or repair.

■  

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent backdrafting. Follow the 
heating equipment manufacturer's guideline and safety 
standards such as those published by the National Fire 
Protection Association (NFPA), the American Society for 
Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.

■  

When cutting or drilling into wall or ceiling; do not damage 
electrical wiring and other utilities.

■  

Ducted fans must always be vented outdoors.

     

CAUTION: 

For general ventilating use only. Do not use 

to exhaust hazardous or explosive materials and vapors.

     

CAUTION:

 To reduce risk of fire and to properly exhaust 

air, be sure to duct air outside - do not vent exhaust air into 
spaces within walls or ceilings, attics or into crawl spaces, 
or garages.

WARNING:

 TO REDUCE THE RISK OF FIRE, USE ONLY 

METAL DUCTWORK.

WARNING: 

TO REDUCE THE RISK OF A RANGE TOP 

GREASE FIRE:

■  

Never leave surface units unattended at high settings. 
Boilovers cause smoking and greasy spillovers that may 
ignite. Heat oils slowly on low or medium settings.

■  

Always turn hood ON when cooking at high heat or when 
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, 
Peppercorn Beef Flambé).

■  

Clean ventilating fans frequently. Grease should not be 
allowed to accumulate on fan or filter.

■  

Use proper pan size. Always use cookware appropriate for 
the size of the surface element.

WARNING: 

TO REDUCE THE RISK OF INJURY TO 

PERSONS IN THE EVENT OF A RANGE TOP GREASE 
FIRE, OBSERVE THE FOLLOWING:

a

 

■  

SMOTHER FLAMES with a close fitting lid, cookie sheet, or 
metal tray, then turn off the burner. BE CAREFUL TO 
PREVENT BURNS. If the flames do not go out 
immediately, EVACUATE AND CALL THE FIRE 
DEPARTMENT.

■  

NEVER PICK UP A FLAMING PAN - you may be burned.

■  

DO NOT USE WATER, including wet dishcloths or towels - 
a violent steam explosion will result.

■  

Use an extinguisher ONLY if:

– You know you have a class ABC extinguisher, and you 

already know how to operate it.

– The fire is small and contained in the area where it 

started. 

– The fire department is being called.

– You can fight the fire with your back to an exit.

a

Based on "Kitchen Fire Safety Tips" published by NFPA.

■  

WARNING: 

To reduce the risk of fire or electrical shock, 

do not use this fan with any solid-state speed control 
device.

Summary of Contents for 32"

Page 1: ...r visit our website at www jennair com In Canada call 1 800 807 6777 or visit our website at www jennair ca Instructionsd installationetGuided utilisationetd entretien Au Canada pour assistance instal...

Page 2: ...t 23 Installation de la hotte 25 Raccordement du circuit d vacuation 25 Raccordement lectrique 26 Installation des cache conduits 27 Achever l installation 27 UTILISATION DE LA HOTTE 28 Commandes de l...

Page 3: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Page 4: ...serve all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial ra...

Page 5: ...supplied with the range hood Use caulking to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold weather installations An additional back draft damper should...

Page 6: ...d OH 44131 5575 A 120 Volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail...

Page 7: ...m rectangular vent IMPORTANT All screws must be installed into wood If there is no wood to screw into additional wall framing supports may be required Remove the template 9 Drill 4 8 mm pilot holes at...

Page 8: ...Remove the 4 mounting screws holding the 8 20 3 cm diameter transition damper to the canopy top Set the damper and mounting screws aside 6 Remove the 4 screws holding the blower motor to the canopy t...

Page 9: ...nopy using 3 of the the screws removed from the 8 20 3 cm diameter transition damper Tighten screws InstallRangeHood NOTE For rear venting installations the 3 x 10 8 3 x 25 4 cm damper must be assembl...

Page 10: ...bottom of the hood exhaust outlet 3 Cut the duct to the measured size X 4 Remove the air deflector 5 Slide the duct onto the bottom of the air deflector 6 Place the assembled air deflector and duct ov...

Page 11: ...ief screw 9 Install terminal box cover 10 Check that all light bulbs are secure in their sockets 11 Reinstall top cover using 5 screws removed previously Tighten screws 12 Reconnect power A Cover scre...

Page 12: ...and light See the Range Hood Use section NOTE To get the most efficient use from your new range hood read the Range Hood Use section RANGE HOOD USE The range hood is designed to remove smoke cooking...

Page 13: ...lease handles are toward the front Insert aluminum filter into upper track 5 Push in spring release handle 6 Push up on metal filter and release handle to latch into place 7 Close the glass cover and...

Page 14: ...BR G GY GRAY GREEN BROWN BLUE Y G Y W R YELLOW WHITE RED YELLOW GREEN COLOR TABLE COLOR TABLE BK R W Y BR Y G GY BU Y BR W R BK BU Y Y Y Y Y Y Y Y Y R R BU BU Y BK R W BR BR BK R W Y BK W BK Y G W Y G...

Page 15: ...nd serial number 3 Name and address of your dealer or servicer 4 A clear description of the problem you are having 5 Proof of purchase sales receipt User s guides service manuals and parts information...

Page 16: ...e service by an authorized Jenn Air servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance...

Page 17: ...n cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Page 18: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Page 19: ...10 8 3 x 25 4 cm 2 chevilles d ancrage mural de 8 x 40 mm 4 chevilles d ancrage mural de 10 x 50 mm Exigencesd emplacement IMPORTANT Observer les dispositions de tous les codes et r glements en vigue...

Page 20: ...uit en plastique ou en feuille m tallique La longueur du circuit d vacuation et le nombre de coudes doit tre r duit au minimum pour fournir la meilleure performance Pour un fonctionnement efficace et...

Page 21: ...our les installations sans d charge l ext rieur recyclage sans cache conduit uniquement Installations sans d charge l ext rieur recyclage S il n est pas possible d vacuer les fum es et vapeurs de cuis...

Page 22: ...et r glements en vigueur INSTRUCTIONS D INSTALLATION Pr parationdel emplacement Il est recommand d installer le circuit d vacuation avant de proc der l installation de la hotte Avant d ex cuter les d...

Page 23: ...nte depuis le tableau de distribution avec fusibles ou disjoncteurs pour r aliser facilement le raccordement dans le bo tier de connexion de la hotte REMARQUE Ne pas mettre le syst me sous tension ava...

Page 24: ...r vers le bas pour l immobiliser et aligner les trous destin s aux vis de montage Installer les vis de montage et les serrer 10 Rebrancher la fiche du ventilateur 11 Remonter la vitre centrale sur l a...

Page 25: ...xt rieur uniquement 1 Installer le circuit d vacuation sur le raccord de transition 2 Serrer le raccord avec des brides de serrage 3 V rifier que les clapets anti retour fonctionnent correctement Pour...

Page 26: ...omologation UL ou CSA 4 Acheminer le cordon d alimentation du domicile travers le serre c ble dans le bo tier de connexion A Vis de montage du clapet A A Vis du couvercle B Couvercle sup rieur AVERTIS...

Page 27: ...des sections sup rieure et inf rieure du cache conduit pousser la section inf rieure vers le bas sur la hotte et soulever la section sup rieure vers le plafond pour installer l aide des deux vis de 4...

Page 28: ...lateur Les boutons FAN SPEED vitesse du ventilateur permettent d allumer le ventilateur et d en contr ler la vitesse ainsi que le niveau sonore ce qui permet de le faire fonctionner sans bruit On peut...

Page 29: ...enfoncer la partie centrale inf rieure pour l embo ter Filtres d installation sans d charge l ext rieur recyclage Le filtre charbon n est pas lavable Celui ci devrait durer pendant six mois dans des c...

Page 30: ...A VE JA BL R JAUNE BLANC ROUGE JAUNE VERT TABLEAU DES COULEURS TABLEAU DES COULEURS N R BL JA MAR JA VE GRIS BU JA MAR BL R N BU JA JA JA JA JA JA JA JA JA R R BU BU JA N R BL MAR MAR N R BL JA N BL N...

Page 31: ...hand ou la compagnie de service ne peut pas r soudre votre probl me crivez Jenn Air Brand Home Appliances Customer eXperience Centre 200 6750 Century Ave Mississauga ON L5N 0B7 Adresse Internet www je...

Page 32: ...n est pas install conform ment aux instructions d installation fournies 11 Les gros appareils m nagers dont les num ros de s rie et de mod le originaux ont t enlev s modifi s ou qui ne peuvent pas tr...