background image

13

Operating the blower

The FAN SPEED buttons turn the fan on and control the fan 
speed and sound level for quiet operation. The speed can be 
changed anytime during fan operation by pressing the desired 
blower speed button.

The FAN OFF button turns the fan Off.

RANGE HOOD CARE

Cleaning

IMPORTANT: Clean the hood and grease filters frequently 
according to the following instructions. Replace grease filters 
before operating hood.

Exterior Surfaces:

To avoid damage to the exterior surface, do not use steel wool or 
soap-filled scouring pads. 

Always wipe dry to avoid water marks.

Cleaning Method:

Liquid detergent soap and water, or all-purpose cleanser

Wipe with damp soft cloth or nonabrasive sponge, then rinse 
with clean water and wipe dry.

Metal Grease Filter

1. Press in the bottom center of the glass cover to release the 

latch. Pull the bottom of the glass cover outward to gain 
access to the internal area of the vent hood.

2. Remove each filter by pulling the spring release handle and 

then pulling down the filter. 

3. Wash metal filters as needed in dishwasher or hot detergent 

solution.

4. Reinstall the filter by making sure the spring release handles 

are toward the front. Insert aluminum filter into upper track.

5. Push in spring release handle.

6. Push up on metal filter and release handle to latch into place.

7. Close the glass cover and press in bottom center to secure.

Non-Vented (recirculating) Installation Filters

The charcoal filter is not washable. It should last up to 6 months 
with normal use. Replace with Charcoal Filter Kit Number 
W10272068.

To replace charcoal filter:

1. Cover the grille that covers the blower motor with the 

charcoal filter so that the slots on the filter correspond to the 
pins on the sides of the motor protection grille.

2. Turn the charcoal filter clockwise to lock it.

3. Repeat steps 1-2 on the other filter.

Replacing a Halogen Lamp

Turn off the range hood and allow the halogen lamp to cool. To 
avoid damage or decreasing the life of the new bulb, do not 
touch bulb with bare fingers. Replace bulb, using tissue or 
wearing cotton gloves to handle bulb.

If new lights do not operate, make sure the lamps are inserted 
correctly before calling service.

1. Disconnect power.

2. Use a flat-blade screwdriver and gently pry the light cover 

loose.

3. Remove the lamp and replace with a 12-volt, 20-watt 

maximum, halogen lamp made for a G-4 base.

4. Replace the light cover.

5. Reconnect power.

A. Spring release handle

A

A. Charcoal filter
B. Pins

C. Blower motor

A

B

C

Summary of Contents for 32"

Page 1: ...r visit our website at www jennair com In Canada call 1 800 807 6777 or visit our website at www jennair ca Instructionsd installationetGuided utilisationetd entretien Au Canada pour assistance instal...

Page 2: ...t 23 Installation de la hotte 25 Raccordement du circuit d vacuation 25 Raccordement lectrique 26 Installation des cache conduits 27 Achever l installation 27 UTILISATION DE LA HOTTE 28 Commandes de l...

Page 3: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Page 4: ...serve all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial ra...

Page 5: ...supplied with the range hood Use caulking to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold weather installations An additional back draft damper should...

Page 6: ...d OH 44131 5575 A 120 Volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail...

Page 7: ...m rectangular vent IMPORTANT All screws must be installed into wood If there is no wood to screw into additional wall framing supports may be required Remove the template 9 Drill 4 8 mm pilot holes at...

Page 8: ...Remove the 4 mounting screws holding the 8 20 3 cm diameter transition damper to the canopy top Set the damper and mounting screws aside 6 Remove the 4 screws holding the blower motor to the canopy t...

Page 9: ...nopy using 3 of the the screws removed from the 8 20 3 cm diameter transition damper Tighten screws InstallRangeHood NOTE For rear venting installations the 3 x 10 8 3 x 25 4 cm damper must be assembl...

Page 10: ...bottom of the hood exhaust outlet 3 Cut the duct to the measured size X 4 Remove the air deflector 5 Slide the duct onto the bottom of the air deflector 6 Place the assembled air deflector and duct ov...

Page 11: ...ief screw 9 Install terminal box cover 10 Check that all light bulbs are secure in their sockets 11 Reinstall top cover using 5 screws removed previously Tighten screws 12 Reconnect power A Cover scre...

Page 12: ...and light See the Range Hood Use section NOTE To get the most efficient use from your new range hood read the Range Hood Use section RANGE HOOD USE The range hood is designed to remove smoke cooking...

Page 13: ...lease handles are toward the front Insert aluminum filter into upper track 5 Push in spring release handle 6 Push up on metal filter and release handle to latch into place 7 Close the glass cover and...

Page 14: ...BR G GY GRAY GREEN BROWN BLUE Y G Y W R YELLOW WHITE RED YELLOW GREEN COLOR TABLE COLOR TABLE BK R W Y BR Y G GY BU Y BR W R BK BU Y Y Y Y Y Y Y Y Y R R BU BU Y BK R W BR BR BK R W Y BK W BK Y G W Y G...

Page 15: ...nd serial number 3 Name and address of your dealer or servicer 4 A clear description of the problem you are having 5 Proof of purchase sales receipt User s guides service manuals and parts information...

Page 16: ...e service by an authorized Jenn Air servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance...

Page 17: ...n cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Page 18: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Page 19: ...10 8 3 x 25 4 cm 2 chevilles d ancrage mural de 8 x 40 mm 4 chevilles d ancrage mural de 10 x 50 mm Exigencesd emplacement IMPORTANT Observer les dispositions de tous les codes et r glements en vigue...

Page 20: ...uit en plastique ou en feuille m tallique La longueur du circuit d vacuation et le nombre de coudes doit tre r duit au minimum pour fournir la meilleure performance Pour un fonctionnement efficace et...

Page 21: ...our les installations sans d charge l ext rieur recyclage sans cache conduit uniquement Installations sans d charge l ext rieur recyclage S il n est pas possible d vacuer les fum es et vapeurs de cuis...

Page 22: ...et r glements en vigueur INSTRUCTIONS D INSTALLATION Pr parationdel emplacement Il est recommand d installer le circuit d vacuation avant de proc der l installation de la hotte Avant d ex cuter les d...

Page 23: ...nte depuis le tableau de distribution avec fusibles ou disjoncteurs pour r aliser facilement le raccordement dans le bo tier de connexion de la hotte REMARQUE Ne pas mettre le syst me sous tension ava...

Page 24: ...r vers le bas pour l immobiliser et aligner les trous destin s aux vis de montage Installer les vis de montage et les serrer 10 Rebrancher la fiche du ventilateur 11 Remonter la vitre centrale sur l a...

Page 25: ...xt rieur uniquement 1 Installer le circuit d vacuation sur le raccord de transition 2 Serrer le raccord avec des brides de serrage 3 V rifier que les clapets anti retour fonctionnent correctement Pour...

Page 26: ...omologation UL ou CSA 4 Acheminer le cordon d alimentation du domicile travers le serre c ble dans le bo tier de connexion A Vis de montage du clapet A A Vis du couvercle B Couvercle sup rieur AVERTIS...

Page 27: ...des sections sup rieure et inf rieure du cache conduit pousser la section inf rieure vers le bas sur la hotte et soulever la section sup rieure vers le plafond pour installer l aide des deux vis de 4...

Page 28: ...lateur Les boutons FAN SPEED vitesse du ventilateur permettent d allumer le ventilateur et d en contr ler la vitesse ainsi que le niveau sonore ce qui permet de le faire fonctionner sans bruit On peut...

Page 29: ...enfoncer la partie centrale inf rieure pour l embo ter Filtres d installation sans d charge l ext rieur recyclage Le filtre charbon n est pas lavable Celui ci devrait durer pendant six mois dans des c...

Page 30: ...A VE JA BL R JAUNE BLANC ROUGE JAUNE VERT TABLEAU DES COULEURS TABLEAU DES COULEURS N R BL JA MAR JA VE GRIS BU JA MAR BL R N BU JA JA JA JA JA JA JA JA JA R R BU BU JA N R BL MAR MAR N R BL JA N BL N...

Page 31: ...hand ou la compagnie de service ne peut pas r soudre votre probl me crivez Jenn Air Brand Home Appliances Customer eXperience Centre 200 6750 Century Ave Mississauga ON L5N 0B7 Adresse Internet www je...

Page 32: ...n est pas install conform ment aux instructions d installation fournies 11 Les gros appareils m nagers dont les num ros de s rie et de mod le originaux ont t enlev s modifi s ou qui ne peuvent pas tr...