Jenaer ecostep 200 Installation Manual Download Page 9

RS232 

1:1 direct connection to a PC COM

RS232 serial interface for

parameter setting,

configuration, controlling

interface for setup by a PC

Fieldbus interface

CANopen, DS 402

Fieldbus interface, RS485 ,

published  protocol

ID setting for

serial network operation

4 LEDs for indication of

device status

quadrature  encoder input

for commutation, torque,

speed  and positioning control

quadrature  encoder input

configurable for pulse and direction

command for electronic gear

 functions

Optional:

absolute value encoder input

(SSI)

max. 2 MHz

RS422

TTL

max. 2 MHz

RS422

TTL

Pin

Signal at PC COM

1

DCD

2

RxD

3

TxD

4

DTR

5

GND

6

DSR

7

RTS

8

CTS

9

RI

D-Sub 9 pin

X 5

RS232

CAN

TTL

RS485

TTL

galvanic insulation

only with Profibus

S0
S1
S2
S3

24 V (gn)

BUS (gn)

RS422

TTL

D-Sub 9 pin male

X 1

CAN

Pin

Signal

1

nc

2

CAN_L

3

CAN_GND

4

nc

5

nc

6

GND

7

CAN_H

8

nc

9

CAN_V+

FIELD BUS 1

D-Sub 9 pin

X 2

FIELD BUS 2

Code Switch
for Network-ID

0...15

Status-LED

ERR (rd)

D-Sub 9 pin

X 7

Master encoder input

Pin

Signal

1

+5V, max. 200 mA

2

A (Clock)

3

B (Direction)

4

N

5

+24V

6

GND

7

/ A (/Clock)

8

/ B (/ Direction)

9

/N

MASTER ENCODER

D-Sub 9 pin

X 6

Motor encoder output

Pin

Signal

1

+5V

2

A

3

B

4

N

5

nc

6

GND

7

/ A

8

/ B

9

/N

 ENCODER OUT

D-Sub 9 pin

X 8

Motor encoder input

Pin

Signal

1

+5V

2

A

3

B

4

N

5

nc

6

GND

7

/ A

8

/ B

9

/N

 ENCODER IN

RUN (gn)

Jenaer Antriebstechnik GmbH

ECOSTEP

 200

S9 (13)

Safety Instructions / Technical Specifications / Installation, Date 09/2007

RS485      Profibus DP

Pin

Signal    Signal

1

frei

   frei

2

Rx +

   frei

3

Tx +

  RxD/TxD-P

4

frei

  CNTR-P

5

GND

  DGND

6

+5V

  VP (+5V)

7

Rx -

  frei

8

Tx -

  RxD/TxD-N

9

frei

  frei

Summary of Contents for ecostep 200

Page 1: ...COLIN 200 Safety Instructions Technical Specifications Installation JenaerAntriebstechnik GmbH Buchaer Stra e 1 D 07745 Jena Tel 49 0 3641 6 33 76 55 Fax 49 0 3641 6 33 76 26 E Mail info jat gmbh de w...

Page 2: ...does not move All electrical connectors of the device must not be neither plugged in nor disconnected under voltage since electric arcs may demage persons and connectors Do not touch components which...

Page 3: ...ional monitoring and protective features are properly installed When connecting the equipment to the power supply ensure that the applicable standards and regulations are complied with the power conne...

Page 4: ...0 m otherwise consult supplier Frequency of output current ripple 16 4 kHz Electrical Specifications Control logic supply 18 30 VDC ripple 10 Fuse of control logic supply recommended 3 A T Bus power s...

Page 5: ...according to DS301 DSP402 max 1 MBaud max 15 nodes max cable length 40 m 1 MBaud max cable length 1 km 50 kBaud RS232 public JAT protocol similar to CANopen DS301 9 6kBaud max 15 nodes max cable leng...

Page 6: ...nt max 0 5 A Holding brake output 24 V max 1 0 0 5 A 100 ms continuous Protection circuits against thermical overload and short circuit to GND Regeneration energy of inductive loads max 0 2 J internal...

Page 7: ...cable braid Connectors for motor X9 and power supply X10 depth 170 without mating connectors Jenaer Antriebstechnik ECOSTEP 200 X1 X5 X2 X3 X6 X7 X4 X8 FIELD BUS 1 RS232 FIELD BUS 2 ENCODER OUT MASTE...

Page 8: ...GND MOTOR A MOTOR A MOTOR B MOTOR B DC BUS DC BUS GND X 4 X 3 Ph nix MC 1 5 3 81 X9 X10 Ph nix IC 2 5 5 08 Ph nix MSTB 2 5 5 08 24V 4mA 1ms digital I O PLC interface for running configurable motion p...

Page 9: ...vanic insulation only with Profibus S0 S1 S2 S3 24 V gn BUS gn RS422 TTL D Sub 9 pin male X 1 CAN Pin Signal 1 nc 2 CAN_L 3 CAN_GND 4 nc 5 nc 6 GND 7 CAN_H 8 nc 9 CAN_V FIELD BUS 1 D Sub 9 pin X 2 FIE...

Page 10: ...Jenaer Antriebstechnik GmbH ECOSTEP 200 S10 13 Safety Instructions Technical Specifications Installation Date 09 2007 Incoming Supply...

Page 11: ...Jenaer Antriebstechnik GmbH ECOSTEP 200 S11 13 Safety Instructions Technical Specifications Installation Date 09 2007 Terminal Connection of ECOBRAX ECOSTEP...

Page 12: ...EMV Installationsschema Jenaer Antriebstechnik GmbH ECOSTEP 200 S12 13 Safety Instructions Technical Specifications Installation Date 09 2007...

Page 13: ...No Connection ECOSTEP X9 3 A 1 A 4 B 2 B Green Yellow PE Brake cable BRM39 Colour Connection ECOSTEP X9 Brown BRAKE White BRAKE Motor encoder cable ENC47 Colour Signal Connection ECOSTEP X9 Red 5V Pi...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Reviews: