background image

Jefferson Tools, Herons Way, Chester Business Park, Chester, CH4 9QR, United Kingdom

T:

 

+44 (0) 1244 646 048     

F:

 

+44 (0) 01244 360 314   

E:

 

[email protected]

www.jeffersontools.com

Do not modify the construction or design of the tank or any other part of this equipment: 

Assemble the tank components in accordance with the instructions contained in this user manual. Do not drill into the tank or weld any  
attachments to it. Do not alter the design by any means or use the equipment for any other use than it is intended. 

 

Only use approved attachments parts and components: 

Use only accessories supplied with this equipment and assembled as shown in these instructions. Do not use non-compatible accessories or re-
placement parts. Contact your nearest authorised Jefferson dealer for advice or telephone 

+44 (0) 1244 646 048 

for advice. 

  

Check pressure tank and accessories for damage and correct assembly before use: 

Never use this equipment if it is damaged in anyway. Never try to repair a broken part - contact your nearest authorised Jefferson dealer for advice. 

Ensure that the equipment is cleaned thoroughly after use and maintained regularly: 

Clean and dry the equipment after each use to prevent blockages caused by dirt and debris. Ensure that the ports to the safety valve gauge and 
outlet are free of hardened paint or other materials which could prevent free movement of air. 

Do not adjust or remove the lid while the tank is under pressure: 

Ensure that the air supply to the equipment is turned off then turn the regulator knob counter clockwise to relieve the air pressure before opening 
the lid. Check that the tank is not under pressure by pulling the safety valve ring.  

Do not use reactive chemicals: 

Using reactive chemicals can damage the lid gasket and safety valve seal increasing the risk of equipment failure under air pressure. Do not use 
halogenated hydrocarbon solvents with this system, which contains aluminium parts and may explode. Cleaning agents, coatings, paints, and 
adhesives may contain halogenated hydrocarbon solvents. Don’t take chances, consult your material supplier to be sure. (e.g. methylene chloride 
and 1,1,1 - Trichlorethane). 

Do not over-tighten the lid clamps:

Over-tightening the clamps can cause weakening of the lid gasket and reduce the effectiveness of the system and increase the risk of accident. En-
sure that the lid gasket is kept clean to avoid leakage. If the gasket is worn or damaged replace it before use, contact your nearest Jefferson Dealer 
for details. 

2. Box Contents : 

Before assembling and using this equipment please ensure that all the items are included in the box and free from damage.

1x 

10L Paint Tank 

1x

 1.8mm Nozzle Spray Gun

1x

 8m Black Paint Hose 

1x 

8m Red Air Hose

1x 

Small Brush

2x 

Assembly and Maintenance Spanners

1x

 Manual

3. Description

This 10L Paint tank is equipped with an air regulator, pressure gauge, safety valve and fluid outlet. The maximum pressure is 

8Opsi.

Please note: 

This equipment is not designed for use with highly abrasive or corrosive materials or those containing rust which can damage internal 

parts and increase the risk of product failure and personal injury. 

Summary of Contents for JEFA052

Page 1: ...ster Business Park Chester CH4 9QR United Kingdom T 44 0 1244 646 048 F 44 0 01244 360 314 E sales jeffersontools com www jeffersontools com Operation Guide www jeffersontools com 10L Paint Pot System...

Page 2: ...lot lights and open flames before spraying 2 Wear a suitable respirator which is approved for the paint product you are using 3 Do not use halogenated hydrocarbon solvents with this system which conta...

Page 3: ...the equipment is turned off then turn the regulator knob counter clockwise to relieve the air pressure before opening the lid Check that the tank is not under pressure by pulling the safety valve rin...

Page 4: ...but not exceeding 50lbs 2 External Mix Guns Use lower paint tank pressure Important Before turning on the air pressure screw out the air regulator T Handle adjusting screw all the way counter clockwis...

Page 5: ...valve ring until the pressure level bleeds down 2 Turn the T Handle adjusting screw on the regulator counter clockwise until no spring tension is felt 3 Loosen the thumb screws tip clamps and tip the...

Page 6: ...Jefferson Tools Herons Way Chester Business Park Chester CH4 9QR United Kingdom T 44 0 1244 646 048 F 44 0 01244 360 314 E sales jeffersontools com www jeffersontools com 7 Parts Diagram...

Page 7: ...Jefferson Tools Herons Way Chester Business Park Chester CH4 9QR United Kingdom T 44 0 1244 646 048 F 44 0 01244 360 314 E sales jeffersontools com www jeffersontools com 8 Parts List...

Page 8: ...effersontools com warranty and completing the online form Online warranty registration is recommended as it eliminates the need to provide proof of purchase should a warranty claim be necessary Warran...

Page 9: ...gainst a third party courier will be dealt with under the terms conditions of their road haulage association directives Step 3 Assessment and Repair On receipt the equipment will be assessed by an aut...

Page 10: ...cturer declare that the following equipment conforms to the requirements of the following Directives Equipment Category Coating Vessels Notified Body TUV SUD Industrie Service IS DBB MUC Westendr 199...

Page 11: ...Jefferson Tools Herons Way Chester Business Park Chester CH4 9QR United Kingdom T 44 0 1244 646 048 F 44 0 01244 360 314 E sales jeffersontools com www jeffersontools com...

Page 12: ...646 048 F 44 0 01244 360 314 E sales jeffersontools com www jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating instru...

Reviews: