Symptom:
ABM INTERNAL
When Monitored and Set Condition:
ABM INTERNAL
When Monitored:
Ignition On - Continuously
Set Condition:
When one of two internal CPUs, fails the programmed self test within the
ABM.
POSSIBLE CAUSES
INTERMITTENT DTC
DAMAGED ABM/ABM HARNESS CONNECTOR
FUSED RUN RELAY OUTPUT CIRCUIT OPEN
ABS VALVE FUSED B(+) CIRCUIT OPEN
ABS PUMP FUSED B(+) CIRCUIT OPEN
ABM - GROUND CIRCUIT OPEN
ABM - INTERNAL FAULT
TEST
ACTION
APPLICABILITY
1
Turn the ignition on.
With the DRBIII
t
, read DTCs.
With the DRBIII
t
, erase DTCs.
Turn the ignition off.
Turn the ignition on.
With the DRBIII
t
, read DTCs.
Does the DRBIII
t
display ABM INTERNAL?
All
Yes
→
No
→
2
Turn the ignition off.
Disconnect the ABM harness connector.
Inspect the ABM/ABM harness connector for damage.
Is there any broken, bent, pushed out, corroded or spread terminals?
All
Yes
→
Repair as necessary.
Perform ABS VERIFICATION TEST - VER 1.
No
→