Programming Guide – 34
To change the command set:
1. Press and hold the GPIB ADDR key while the SB switch powers up. The active interface
setting is displayed.
2. Press
the
▲
key to scroll to the required command set, for example, SB, SC, or SX.
3. Press
the
GPIB
ADDR key to save the setting.
SC Series Switch Command Set (SCXXX-0XXX Models)
The syntax and functions for the SC series switch commands are provided in Table 12.
Table 12: SC Switch Command Set
Syntax
Function
AnE
switch to channel n
FE
verify channel
XE
turn external driver on
YE
turn external driver off
Response messages (Table 13) are formatted as qn, where q is the switch status (A = normal,
I = syntax error, C = calibration error), and n is the channel number.
Table 13: Response Messages for SC Switch Commands
Status Byte Register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Message
0
0
0
0
0
0
0
BUSY
0
0
0
0
0
0
1
NORMAL
0
RQS
0
0
0
0
1
CAL ERROR
0
RQS
0
0
1
0
1
BAD DATA
0
RQS
0
0
1
1
1
UNIT FAILURE