![JDS Uniphase SB Series User Manual Download Page 15](http://html1.mh-extra.com/html/jds-uniphase/sb-series/sb-series_user-manual_3592512015.webp)
General Information and Specifications – 10
Table 3: Operating Specifications
Local control
•
Step-up,
step-down
channel
selection
•
Control of one external relay driver
•
IEEE 488.1 address selection
•
Return-to-local
function
•
Language
selection
Remote
control
•
GPIB
interface:
IEEE 488.1 1987 capability SH1, AH1, T6, L4, SR1, PP0, DC1, C0, E1
•
RS232
interface:
setting 8 bits, 1200 baud, 1 stop bit, no parity
Command set
Revised command set. Capable of emulating command set of JDS
Uniphase SC-0 and SX-0 Series switch models.
Drivers
Eight open collector outputs, sink current 100 mA maximum per output
(driver):
•
Drivers 1, 2, 3, 4, +5V, and GND (ground) are accessible from back
panel connector
•
Drivers 5, 6, 7, and 8 are internal
•
Driver 1 can also be controlled from the DRIVER1 key on the front panel
Warm-up time
1
1 hour at 25 °C ambient temperature
1
Applicable for optimum repeatability performance.
Table 4: Other Specifications
Electrical
Input voltage
100 to 240 V AC, 50 to 60 Hz
Power consumption
80 VA maximum
Physical
Dimensions (W x H x D)
standard
with rack-mount kit
1
21.2 x 8.9 x 35.5 cm
48.3 x 8.9 x 35.5 cm
Weight
3.75 kg
Environmental
Operating temperature
0 to 55 °C
Storage temperature
-40 to 70 °C
Humidity
maximum 95% RH from 0 to 55 °C
1
Rack-mount kit is optional.