Programming Guide – 33
equipped with a serial port. COM port 2 of the computer is designated as the serial port and is
connected to the switch.
Before using any of these examples, ensure that the active interface command set is SB.
The RS232 interface cannot receive an SRQ interrupt.
The RS232C commands that appear in this section do not always show the terminating
character <CR>; however, it is implied.
Sending Commands
OPEN "COM2:1200,N,8,1" FOR RANDOM AS #3
A = 10
PRINT#3, "CLOSE ";A
PRINT#3, "XDRS 255"
END
Querying Status
This example queries and displays the current channel setting.
PRINT#3, "CLOSE?"
INPUT#3, A
PRINT A
END
Reading the Status Register
The serial polling function is not supported on any RS232 interface, but STB? can be used to
query the status register since the query command performs the same function as serial
polling.
This example changes the channel setting and reads the status register continuously until the
output has settled.
OPEN "COM2:1200,N,8,1" FOR RANDOM AS #3
PRINT#3, "CSB"
' clear status register
PRINT#3, "CLOSE 5"
DO
' loop until motor settles
PRINT#3, "STB?"
INPUT#3, SR1
LOOP UNTIL (SR1 AND 4)
PRINT SR1
END
Setting the Interface Command Set
The SB switch can be set to emulate the interface command sets of earlier models of JDS
Uniphase SC Series and SX Series switches.
Summary of Contents for SB Series
Page 1: ...SB SERIES FIBEROPTIC SWITCH User s Manual...
Page 2: ......