- DT-004 Downloading
(con’t)
8. While downloading, the download status LEDs on the DT-004
will illuminate, indicating status of the download.
7. To begin the download process, press the “START” button. The
“RDY” LED will begin to blink.
9. When the downloading is complete, the “OK” LED will light
and a buzzer will sound for about a second.
10.Press the “RESET” button once, then press the “VERIFY”
button once. After approximately 10 seconds, a buzzer will sound
for about a second, and the “OK” LED will illuminate.
11.Turn power on the DT-004 to the “OFF” position, remove the
harness connectors from the unit, and return the Dip switches to
their normal operating positions.
12.To repeat the process with other units, follow these instructions from
#3 through #10.
NOTE:
After downloading/upgrading, recalibrate the units using the
calibration/reference paper, Part No. 501-00032 to ensure proper