Error Code Table 3
Return code.
Number of pulses
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Reason for return
Crooked insertion
Magnetic pattern error
A sensor other than DT1, PT2 detected a bill
while the acceptor was on standby.
The dark-light ratio of the bill is below the fixed value
Level error; the bill is unusually dirty.
Two overlapping bills were detected.
Error in a photosensor
Returned an illegal bill type.
Reserved
(1) The *HPC sensor did not detect the bill within the
specified period after it was initially taken in.
(2) The *HPL *HPR, did not delect the bill
within the specified period after it was initially
taken in.
(3) The feed sensor did not detect the bill within the
specified period after it was initially taken in.
Reserved
Stacker lever trouble.
Bill length error.
Color pattern error.
None of the *HPR, *HPC, nor *HPL detected a bill when the type of bill
signal is output.
The feed-in sensor stops detecting a bill before the *HPC sensor during
transfer of bill to cash box.
The HPC sensor detected a bill again during transfer of bill to cash box.