MA
G HEAD
TEST BO
ARD
MC
-01
Mag tool
(Part #: 041793)
Align the second line of mag head test board
just above the roller of acceptor head lower tray
Adjust peak level. Push Enter key to start.
MAG GAIN ADJUST
MAG Center A/D = 0.8v (41) PEAK: 0.84v
(a)
(b)
<scr 10>
MA
G HEAD
TEST BO
ARD
MC
-01
(12) Calibrate the magnetic sensor(s). Insert the mag head test board to the acceptor and find a location where
the second line of mag head test board just above the roller of acceptor head lower tray (show the diagram
below) Make sure that the tabs on both side of the acceptor head are firmly locked.
Closing the
acceptor head after the calibration starts results in an error
.
(13) Press the ENTER key. Screen 10 appears. (a) shows the current value and (b) shows the peak value
detected after the mag board has been inserted.
(14) Slowly move the mag-head test board back and forth to find the peak value.
The peak value (b)
should be between 0.5V and 1.2V.
(15) Continue to move move slowly the MAG head test board back and forth several millimeters to find the
position
where the “MAG Center A/D” value enters the range within -0.1V in relation to the peak
value
.
Mod
elnumbers
Spe
c
ificati
o
n
s
Operatio
n Ma
nual
C
o
mmun
icati
on
Spe
c
ificati
o
n
s
Disassembly
Assembly
W
iring Diagram
Tr
ouble S
h
o
o
ting
Cali
brati
on
So
ft
ware
Do
wn
lo
ad
Pa
rts List
WBA-SS Service Manual
- 6 -