P/N 960-000180R_Rev. 1 {EDP #233427}
© 2016, JAPAN CASH MACHINE CO., LTD.
6 - 3
Calibration and Testing
DBV® Series DBV-400 Banknote Validator
Section 6
5.
When the USB Driver Installation is complete,
the “
Completing the Device Driver Installation
Wizard
” Screen will appear as shown in Figure 6-
10. Click on the “
Finish
” Screen
Button
a
) to close the Screen.
This completes the DBV-400 USB Driver Software
installation procedure.
JCM Tool Suite Standard Edition
Mode
The following two (2) mode feature types exist in
the “
JCM Tool Suite Standard Edition
” package:
•
Normal Mode
•
Test Mode
“
Normal Mode
” is a mode designed to provide the
DBV-400 Operating Software to be downloaded.
The “
Service Mode
” contains three (3) available
choices (shown in Figure 6-11
) as follows:
•
Download
(for downloading software)
•
Statistics
(for observing log data)
•
Event Log View
(for confirming Event Log)
“
Test Mode
” is a mode designed to perform DBV-
400 Calibration and Performance Testing. The
“
Service Mode
” contains five (5) available choices
in its Pull-down Menu (Figure 6-12
) as follows:
•
Download
(for downloading software)
•
Statistics
(for observing log data)
•
Sensor Adjustment
(for calibration)
•
Performance Test
(for Performance Testing)
•
Event Log View
(for confirming Event Log)
Download Procedures
The following two (2) procedures are available to
download the DBV-400 Software Program:
•
The DBV-400 Software Program is loaded on the
Unit (Normal)
•
The DBV-400 Software Program is not loaded on
the Unit (e.g., after replacing the CPU Board)
Software Program Download
To download the DBV-400 Software Program,
proceed as follows:
1. Remove electrical power from the DBV-400 Unit.
2. When
upgrading
the
Software in Normal
condition, set all of the 8-position DIP Switches
of DIP Switch Block 1 (
DIP SW1
) to
OFF
When downloading to a Unit (Software not
previously installed), set DIP Switch Block 1
(
DIP SW1
) Switches #6, #7 and #8 to
ON
3. Connect the USB Port on the DBV-400 Unit to
the PC (Refer to Figure 6-1 and Figure 6-2 for
Tool Requirements and Harness Connector loca-
tions).
4. Apply
electrical
power to the DBV-400 Unit.
Hardware Update Wizard Screen 1
Figure 6-9
Hardware Update Wizard Screen 1
a
Hardware Update Wizard Screen 2
Figure 6-10
Hardware Update Wizard Screen 2
a
NOTE: If the Windows Security Screen
appears, select “Install this Driver Software
(I)” to proceed.
Figure 6-11
Normal Mode Selection
Figure 6-12
Test Mode Selection
Figure 6-13
Figure 6-13
Normal Upgrade Setting
ON
1
2
3
4
5
6
7
8
Figure 6-14
Figure 6-14
Initial Download Setting
ON
1
2
3
4
5
6
7
8