P/N 960-000180R_Rev. 1 {EDP #233427}
© 2016, JAPAN CASH MACHINE CO., LTD.
2 - 1 1
Installation
DBV® Series DBV-400 Banknote Validator
Section 2
Cleaning Procedure
To clean the DBV-400 Validation Section, use a
soft, dry (or slightly damp with water) lint-free
Micro-fiber Cloth or a vacuum cleaner.
Do not use any alcohol, solvents, citrus based
products, or scouring agents that may cause
damage to the Validation Section Sensors and/or
Rollers.
Sensor and Roller Cleaning Procedure
To clean the DBV-400 Unit’s Sensors and Rollers,
proceed as follows:
1. Turn the Power Supply to both the DBV-400
Unit
and the Host Machine
OFF
.
2. Remove the Cash Box from the DBV-400 Unit
(Figure 2-3 or Figure 2-4) and pull the Validation
Guide out of the DBV-400 Unit (Figure 2-6).
3. Clean the appropriate path and Lens of each
Sensor (See Figure 2-10 for Sensor and Roller
locations & Table 2-12 for each Sensor Type
cleaning method).
Caution: Do not use alcohol, thinner or
citrus based products for cleaning any
Banknote Transport Sensors or
surfaces. The lenses can become
clouded by chemical evaporation
residue that may cause acceptance
errors.
Caution: Do not place a vacuum cleaner
nozzle directly on the surface of the
DBV-400 Unit, to avoid scratches to the
Sensor Lens.
Figure 2-9
Figure 2-9
General Cleaning Image
Lens
Roller
Lint-free Micro
Before
Cleaning
After
Cleaning
Belt
Cotton Swab
fiber Cloth
NOTE: Calibration is recommended after
cleaning.