December, 2006
© 2006, JCM American, Corporation
1 8
1 1
Lecture Notes
Lecture Notes
P
ALM
A-66US
Palm A-66US is used to configure, service, and diagnose the A-66.
Using Palm A66US
To use the Palm A-66 Application perform the following steps:
1. Connect the Palm PDA to the A-66 using the Palm Dongle Cable Assembly.
2. Run
'Palm A66US' (See Figure 17 a)
.
The main menu will display the following three (3) user-interactive mode
selection buttons:
Settings, Service,
and
Diagnostics
.
3. Select the
‘Settings’
Screen Button. The program now offers the following 5
sub-menus to choose from (
Operating Modes, Inhibit Mask, Coin Settings,
Recycler, and Other Settings
) as shown in Figure 19.
Figure 18
A-66US Main Screen
a
Figure 17
Palm A-66US Selection
a
LED INDICATORS & TROUBLESHOOTING
F
RONT
P
ANEL
LED - I
NDICATIONS
AND
T
ROUBLESHOOTING
•
Green LED lit
—
power applied, normal operation indicated (See Figure 4)
•
Green LED flashing
—
A-66 is in the 'coin filling mode'. Coin filling mode is
entered by pressing the Plus
Keypad Button one (1) time. If the A-66 is left in
this mode for more than 30 seconds without detecting any coin activity, it will auto-
matically reset and return to normal operation.
•
Green and Yellow LED lit
—
An inhibited coin was inserted. Check Vending
Machine settings. A possibility exists that high value coins were inhibited due to
empty coin tubes.
+
Figure 4
Quick Diagnosis with the Help of the Pilot Lights