ROLL868 DMR / ROLL868 DMR-P 

 

 

+

-

Fit the rear of the box to the wall using the raw plugs and screws supplied. Pass the cables through the bottom of the equipment. 
Proceed with the starting up of the equipment. 

 

STARTING UP 

 

1.

 

Connect the motor and the power supply. 

 

Connect the motor as shown in the figure above: U (open), V (close), W (common). 
Connect the equipment to the 230Vac power supply as shown in the figure above. The red pilot light is activated every 5 
seconds indicating the correct power supply to the equipment. 
 

2.

 

Set the switch selector to the desired operating option. 

 

Selector 

Position ON (default option) 

Position OFF 

1  

Dead  man  operating:

  the  control  panel  operates  in 

dead  man  mode  for  open  and  close,  provided  it 

is operated  from inside  the coverage  area,  previously 

adjusted. 

Semi-automatic  operating:

  The  control  panel  operates  in 

semi-automatic  mode  for  open  (maximum  manoeuvre  2 

minutes), 

without 

restriction 

on distance between 

transmitter and  receiver, and  in  dead  man  mode  for  close 

(provided it is operated from inside the coverage area). 

 

3.

 

Programming the dead man transmitters.  

Press the programming button PROG for 1 sec: the programming pilot light will come on and the equipment will emit an 

acoustic signal. Press any channel of the transmitter, and wait to hear a 0,5 seconds acoustic signal. 

Configuration of the transmitter programming into the receiver

 

Led R1

 

Pressing any channel of the transmitter, the relays will be activated by: 1rst channel Open and 2nd channel Close, and 

3rd channel Open, 4th channel Close

 

ON 

Note: This control panel only works with dead man transmitters. 

Every time a transmitter is programmed, the equipment will issue an acoustic signal for 0.5 sec.  
After 10 seconds without programming or by pressing the programming button, the equipment will exit programming mode, 

issuing two 1 sec. acoustic signals. If, on programming a transmitter, the equipment memory is full, it will issue seven 0.5 
sec. acoustic signals and exit programming. 
 

4.

 

Set transmitters distance activation.  

The unit is supplied with the activation distance set at the minimum. 
Turn the potentiometer clockwise (to + position) to increase the activation distance 
of the transmitters. 

Turn the potentiometer to – position to decrease the activation distance of the transmitters. 
 
It is the responsibility of the installer that the selected distance allows the user to have direct view of the door as it is in 

motion. 
It is recommended to mark this distance with the door closed, and then to verify that the door can be opened and closed 
from both sides of it. 

 

If the dead man transmitter is not situated in the activation zone, the LED blinks and three beeps will be heard. In this case 

it is necessary to increase the activation distance. 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING: In accordance with the EN 13241-1 and EN 12453-1  

standard

 

concerning pressure maintained control devices: 

 

1.

 

« the person operating the door must have a direct view of the doorway, must be near the 

door (5 meters maximum) during movement of the door and should not find itself in a 

dangerous position »  

Any adjustment of the radio range out of these recommendations, undertakes the installer in 

terms of responsibility for injury or damage. 

 

2.

 

« Releasing of the pressure maintained control device should stop the door movement before 

it scrolls 5cml » . This implies a maximum speed of the door of 12.5 cm / s. 