Adjustment of the receiver / Operating modes
↑
ON
Any change in the configuration of the switches needs a
reprogramming of the system (see "Programming").
↓
OFF
Interference detector
SW1
↑
7 s
The equipment is switched to safety state after 7s.
↓
265
ms
The equipment is switched to safety state after 265ms.
Operating mode with optical safety edges
SW2
↑
ON
In ON mode, only "always on" optical safety edges (OSE-
S7502B and OSE-S7502) are permitted, as the optical ele-
ment always is on.
↓
WORK
In WORK mode, the optical elements are OFF meanwhile the
ATEST signal is active. So it is necessary to disconnect this
ATEST signal during the door movement.
With resistive or mechanical safety edges, the selector does not work because it is
not necessary to activate the sensors.
R3 function
SW3
↑
Low
battery
In low battery indication mode, the relay contact is closed
when any of the transmitters has an insufficient level of bat-
tery.
↓
Alarm
In ALARM mode, the relay contact is closed to indicate that
any of the safety edges stored in the receiver are active.
jcm
technologies
10