P/N 960-000169R_Rev. A {EDP #217859}
© 2012, Japan CashMachine Co., Limited
1 9
VEGA-RC Twin™ Series Banknote Recycler Integration Guide
W
ARNING
C
ODES
When the following errors occur, they can be cleared automatically in five (5) seconds, but future perfor-
mance is not guaranteed. For this reason, replacing the CPU Board is recommended.
M
ACHINE
L
OCK
-
UP
E
RROR
C
ODES
When the following errors occur, the unit will stop operating.
35
[Dispense/Retrieving error - lower] Banknote jam
occurs within the VEGA-RC Twin™ Unit.
Verify there is not a Banknote jam, or an in-path
foreign object. Also, check that assemblies are
properly connected and/or harnessed, and all
unit sensors are clean. Recovery movement will
start after removing the jam.
36
[Dispense/Retrieving error - lower] Banknote jam
occurs at the VEGA™ insertion slot.
Table 11
Warning Codes
Error
Codes
LED Indication
Possible Fault Causes
Corrective Action Required
98
Program rewriting time is over limit (more than
1,000 occurrences).
[Warning issued for over limit program rewriting
because that is limited to 1,000 times.]
When program rewriting time has occurred over 1,000
times, this error code will appear for five (5) seconds
and every time thereafter.
99
EEPROM malfunction.
Warning issued if an abnormal EEPROM
reading occurs.
Change the CPU Board. [When this occurs, EEPROM
data, such as the number of accepted Banknotes,
errors, the total number of errors, the operation log,
dispense times, and serial number will be lost.]
Table 12
Machine Lock Error Codes
Error
Codes
LED
Indication
Possible Fault Causes
Corrective Action Required
01
The VEGA-RC Twin™ Upper Brushless Motor
is not moving - VEGA-RC Twin™ Motor
abnormality error.
Check that the assemblies are properly connected and/or
harnessed, and all of the unit’s sensors are clean.
02
The VEGA-RC Twin™ Lower Brushless Motor
is not moving - VEGA-RC Twin™ Motor
abnormality error.
Check that the assemblies are properly connected and/or
harnessed, and all of the unit’s sensors are clean.
05
Receive different denomination information
(money class) during communication.
Check that the VEGA-RC Twin™ stacking denomination
matches the VEGA™ limit’s command denomination
(confirm that both denomination settings agree).
06
VEGA™ Unit Motor abnormal error.
Motor encoder signal not received from
VEGA™ Unit.
Check that the assemblies are properly connected and/or
harnessed, and all of the unit’s sensors are clean.
07
Abnormal INHIBIT information.
The VEGA™ Unit’s denomination setting for the VEGA-RC
Twin™ is INHIBITED. Check that the VEGA™ Unit’s
denomination settings match the VEGA-RC Twin’s
denomination settings.
08
Using a 24V DC Supply for a 12V DC
specification.
Check that the working voltage is for the related Circuit
Board.
09
Using a 12V DC Supply for a 24V DC
specification.
Check that the working voltage is for the related Circuit
Board.
10
EEPROM writing error - Failed to write data
into EEPROM normally.
Change the CPU Board.
16
The Brushless Motors for transport is not
moving - VEGA-RC Twin™ Motor abnormality
error.
Check that the assemblies are properly connected and/or
harnessed, and all of the unit’s sensors are clean.
17
VEGA’s Flapper is ON when the VEGA-RC
Twin™ “initialization” process is over.
Table 10
Operation Error Codes (Continued)
Error
Codes
LED Indication
Possible Fault Causes
Corrective Action Required
x 7 Times
x 8 Times
NOTE: Dispensing performance from the VEGA-RC Twin will have an abnormal termination anytime a
Banknote remains on one of the sensors in the VEGA Unit. The Banknote being processed is counted as a
dispense completed Banknote.
NOTE: When a command from the host machine is being received or an electrical power failure occurs before
the dispensing process begins, the processing Banknote is counted as a dispense completed Banknote.
x 5 Times
x 6 Times
Lit
Lit
Lit
Lit
Lit
Lit
Lit
Lit
Lit
Lit