Section 8
iVIZION™2 Series Banknote Validator Foundation of Intelligent Validation
Troubleshooting
© 2022, JAPAN CASH MACHINE CO., LTD.
3 6
LED Reject Codes; Barcode Ticket
Green
Flashes
(13)
Banknote Length Error
A Banknote was rejected
because it was longer than
the acceptable length
•
Check that the Banknote is a proper
length
•
Length of the Banknote
Green
Flashes
(14)
Reserved
-
-
Green
Flashes
(15)
Authentic Banknote Iden-
tify Error
A Banknote was rejected due
to the authentic Banknote
Validation result
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Sensors of the Validator
Green
Flashes
(16)
Detected Holed-Note
A Banknote was rejected
because it was holed
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Sensors of the Validator
Green
Flashes
(17)
Detected Worn-Out-Note
A Banknote was rejected
because it was worn out
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Sensors of the Validator
Green
Flashes
(18)
Detected Dog-Ear-Note
A Banknote was rejected
because its corner was folded
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Sensors of the Validator
Green
Flashes
(19)
Detected Dyed-Note
A Banknote was rejected
because it was inked
•
Clean the relative Sensor(s) if they are
dirty or foreign objects are adhering to
them.
•
Calibrate the relative Sensor(s) as
needed.
•
Sensors of the Validator
Table 25
LED Reject Codes; Barcode Ticket
Status LED
Error
Solution
Relative Part/Sensor
Green
Flashes
(1)
Unconfigured Barcode Ticket
Barcodes cannot be detected or
were detected on both sides
facing up and down.
•
Check that a proper Barcode Ticket
is used.
•
Check that the Barcode Ticket is not
damaged or looks unnatural
(abnormal printing, etc).
•
Check that the relative Part(s) are
properly assembled and/or Harness
are connected.
•
Clean and calibrate the relative
Sensor(s).
•
Barcode Ticket
•
CIS
•
MGU Gear
•
Belts of the Validator
•
Motors of the Validator
Green
Flashes
(2)
Format Error
A Barcode Ticket was rejected due
to the number of characters and/
or wide-to-narrow ratio
•
Check that a proper Barcode Ticket
is used.
•
Check that the Barcode Ticket is not
damaged or looks unnatural
(abnormal printing, etc).
•
Check that the relative Part(s) are
properly assembled and/or Harness
are connected.
•
Clean and calibrate the relative
Sensor(s).
•
Barcode Ticket
•
CIS
•
MGU Gear
•
Belts of the Validator
•
Motors of the Validator
Table 24
LED Reject Codes; Banknote (Continued)
Status LED
Error
Solution
Relative Part/Sensor
Summary of Contents for iVIZION2 Series
Page 6: ...P N 960 000231R_Rev A 2022 JAPAN CASH MACHINE CO LTD iv THIS PAGE INTENTIONALLY LEFT BLANK...
Page 8: ...P N 960 000231R_Rev A 2022 JAPAN CASH MACHINE CO LTD v i THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...P N 960 000231R_Rev A 2022 JAPAN CASH MACHINE CO LTD viii THIS PAGE INTENTIONALLY LEFT BLANK...