JCB-SH140D
Instruction & User Manual
25
Screw
Ignition Electrode
Ignition Wires
Spark Gap
Burner Head
Maintenance and Care – Ignition Electrode
Clean and re-gap every 600 hours of operation, or replace as needed.
>
Remove Ignition Wires. These are Push/Pull fit
>
Remove the screw that secures the Ignition Electrode. Now Remove the Ignition Electrode
>
After removing the electrode, clean the terminals with a wire brush.
>
Re-gap the terminals to 0.14’’(3.5mm) if required.