Page 1: ...SPACE HEATER INSTRUCTION USER MANUAL EN JCB SH140D Original Instructions IM DH140D EN...

Page 2: ...ng Safety Box Contents Assembly Operation Fuelling De Fuelling Operation Theory Fuelling the Heater Ventilation Starting Stopping Restarting Maintenance and Care Storage Maintenance Safety Notice Drai...

Page 3: ...E MACHINE Keep for future reference and pass it on if the machine is loaned or sold to another user This manual has been produced by Genpower Ltd and should be kept with the product Please read and un...

Page 4: ...g electric and electronic waste The product should not be discarded with household waste but must be returned to a collection system which conforms to the European Directive 2012 19 EU It will then be...

Page 5: ...ts and other people not using the unit away from the work area Be alert and shut off the unit if anyone enters work area Keep children under the watchful care of a responsible adult Stay alert watch w...

Page 6: ...fuel leaks Keep the machine in safe working condition Do not use the machine if the switch does not turn off the machine when running Any machine that can t be controlled with the switch is dangerous...

Page 7: ...ry 29kW hr or heater rating Minimum clearance from combustibles Top 250cm Side 250cm Front 250cm During Use Walk never run with the machine Be very careful when pulling the machine toward you You must...

Page 8: ...use duct work in front or at rear of heater NEVER move or handle heater while still hot NEVER transport heater in a vehicle with fuel in its tank If equipped with a thermostat the heater may start at...

Page 9: ...upon owners Power cables and plugs should always be regularly inspected for safety If in doubt about electrical safety you must consult a qualified electrician WARNING Risk of electric shock Use only...

Page 10: ...soning symptoms are similar to flu food poisoning viral infections and simply tiredness Itis quite common for people to mistake this very dangerous poisoning for something else To avoid carbon monoxid...

Page 11: ...vapors Do not operate the machine with known leaks in the fuel system Fire hazard keep fuel away from all sources of ignition for example heaters lamps sparks from grinding or welding DO NOT carry out...

Page 12: ...sources of ignition near the area of operation Always stop the engine and allow it to cool before filling the fuel tank Never remove the cap of the fuel tank or add fuel while the engine is running or...

Page 13: ...e of acid Lead acid battery dilute sulphuric acid Nickel cadmium potassium hydroxide alkali electrolyte Use fresh running water to wash off excess electrolyte continue this until medical assistance ar...

Page 14: ...warm Take regular breaks All of the above precautions may help reduce the risk of white finger disease but not rule out the carpaltunnel syndrome Long term and regular users are therefore recommended...

Page 15: ...loss or damage from the hazards of fire soot production explosion burns asphyxiation or carbon monoxide poisoning Only persons who can read and understand these instructions should use or service this...

Page 16: ...JCB SH140D Instruction User Manual 16 COMPONENT LIST 2 3 4 5 7 6 9 8 11 10 1...

Page 17: ...show both the Room Temperature and the machine Temperature 6 Thermostat Knob Alters the Temperature of the machine 7 Power LED This indicates whether the machine has a power supply 8 Fuel Cap 9 Fuel G...

Page 18: ...ge caused during shipping Lay the contents out and check them If any part is damaged or missing you must not use the machine Contact Genpower Ltd Power immediately You must keep the packaging material...

Page 19: ...lower axle holes are facing toward the front of the machine 2 Repeat for the Rear Mounts ensure the holes for the Rear Handle are facing the rear of the machine 3 Repeat on both sides of the machine 4...

Page 20: ...ny fuel that is not approved above NOTE Diesel 1 K kerosene should only be stored in a blue container that is clearly marked Diesel 1 K kerosene Never store diesel 1 K kerosene in a red container Red...

Page 21: ...e to start your heater Electrical System Protection The heater s electrical system is protected by a circuit breaker that protects the system components from damage If the heater fails check the fuse...

Page 22: ...cord 4 Turn the Thermostat control knob to the desired temperature 5 Press the Power Switch into the On position The Power LED and Temperature screens will now be activated Power LED Thermostat Knob O...

Page 23: ...ring the machine Long Term draining the tank is required Old out of date Kerosene and Diesel can damage your heater Before draining tank ensure a suitable container is located below the Drain Hole Ens...

Page 24: ...er in operating correctly The photocell should be cleaned at least once per heating season or more depending on condition Use a cotton swab dipped in water or alcohol to clean the lens of the photocel...

Page 25: ...on Electrode Clean and re gap every 600 hours of operation or replace as needed Remove Ignition Wires These are Push Pull fit Remove the screw that secures the Ignition Electrode Now Remove the Igniti...

Page 26: ...n or less depending on conditions NOTE Use of diesel 1 K kerosene may require additional maintenance Fan Blade Set Screw Motor Shaft Outlet Air Filter Lint Filter Filter Cover Maintenance and Care Fan...

Page 27: ...nozzle front it may be necessary to soak nozzle in clean diesel 1 K kerosene to help loosen any particles Burner Head Screw Spark Plug Ignitor Wire Ignition Wire Ignition Wire Burner Nozzle Nozzle Fac...

Page 28: ...fuel filter ensure a suitable cloth is ready as fuel spillage is likely Use of diesel may require additional maintenance Improper maintenance can lead to poor combustion and soot production Remove Con...

Page 29: ...river turn relief valve Clockwise to increase the fuel pressure Turn Counter clockwise to decrease Correct pump pressure is 38Kpa 5 5Psi For best measurement of pressure test with full tank of fuel Op...

Page 30: ...t board wiring diagrams 8 Igniter wire not connected to spark plug 8 Re attach igniter wire to spark plug 9 Detective igniter 9 Replace igniter Fan does not operate when heater is plugged in and power...

Page 31: ...D Heat Output kW 37 Heat Output BTU 126 250 Fuel Consumption L hr 3 8 Fuel Tank Capacity L 38 Fuel Type Kerosene Diesel Heating Area m3 800 Pump Pressure Kpa Psi 38 5 5 Power Supplier 230V 50Hz 5A Pha...

Page 32: ...e whenever necessary Our latest manuals are also placed online All our manuals can be downloaded at www jcb tools co uk Returning Your Product If you are returning your product please contact the deal...

Page 33: ...Talk To Our Experts Our friendly aftersales team will be more than happy to help you Phone Call our team on 01646 687 880 Email aftersales genpower co uk Post Genpower Ltd Isaac Way Pembroke Dock Pem...

Page 34: ...ible with the environment We are a Member of the VALPAK National Compliance Scheme and our registration number is RM08660 For further information about disposal please contact your Local Authority You...

Page 35: ...er Declare that the product Description 37kW Space Heater Type JCB SH140D Function Space Heating Complies to the Following Directives Low Voltage Directive 2014 35 EU Energy Related Products ERP 2009...