![background image](http://html1.mh-extra.com/html/jcb/5-5-21-roto/5-5-21-roto_quick-start-manual_3591366028.webp)
28
Please see operator manual for full details.
Troubleshooting/FAQs
Issue / FAQ
Resolution / Answer
Can’t operate sway function
•
I
s boom below 3m?
•
Is machine slewed forwards (+/- 5 degrees)?
•
Is axle lock off?
Can’t operate outriggers
•
Are the switch backlights off?
•
Boom must be below 3m height
•
Retract boom to <7.3m extension
•
Ensure control isolation switch isn’t pressed
•
Machine doesn’t have to be stationary to extend/retract legs
(only <5kph).
•
No interlock for manual outriggers on chassis angle. Chassis
angle only interlocked for auto outrigger functionality.
Upper structure service can’t
operate
•
Is LH pod down?
•
Is an attachment selected and confirmed?
•
Is control isolation switch on the joystick pressed?
•
Have you used the joystick activation button?
28