background image

18z-1, 19c-1, 19c-1 EP

8

9

Please see operator manual for full details.

Cab & Switch Panel

 

A

  Graphic symbol

 

B

  Light bar

 

C

  3 way position switch 

 

D

  2 way position switch / momentary switch

Fig 7

 About the Product

 Console Switches

25

9831/2900-1

25

Console Switches

General

For: 16C-1, 18Z-1 ..................................................................................................................... Page 25

For: 19C-1 ................................................................................................................................  Page 26

(For: 16C-1, 18Z-1)

The installed switches and their positions can change according to the specification of the machine.

Each switch has a graphic symbol to show the function of the switch. Before you operate a switch, make sure

that you understand its function.

The rocker switches have two or three positions (as shown).

If the switch has a backlight, then the graphic symbol illuminates when the ignition switch or side lights are

in the on position.

The light bar illuminates to show that the switch function is active.

Figure 18.

1

3

2

A

B

A

Graphic symbol

B

Light bar

 About the Product

 Console Switches

25

9831/2900-1

25

Console Switches

General

For: 16C-1, 18Z-1 ..................................................................................................................... Page 25

For: 19C-1 ................................................................................................................................  Page 26

(For: 16C-1, 18Z-1)

The installed switches and their positions can change according to the specification of the machine.

Each switch has a graphic symbol to show the function of the switch. Before you operate a switch, make sure

that you understand its function.

The rocker switches have two or three positions (as shown).

If the switch has a backlight, then the graphic symbol illuminates when the ignition switch or side lights are

in the on position.

The light bar illuminates to show that the switch function is active.

Figure 18.

1

3

2

A

B

A

Graphic symbol

B

Light bar

Fig 6

 A

  Auxiliary pedal

 B

  Track Controls

 C

  Swing left/ right

 D

  Heater Controls

 E

  Horn

 F

  Excavator arm controls

 G

  Dozer control lever

 H

  Ignition switch

 J

  Right console switches

 K

  Hand throttle

 

L

  Instrument panel

 

M

  Radio (if installed)

 

N

  Operator seat

 

P

  Control isolation lever

 

Q

   Undercarriage track  

extension lever

 

R

  Fire extinguisher (18z-1)

 

S

  Fire extinguisher (19c-1)

 

T

  Window washer bottle

Operator Station Layout – 18z-1, 19c-1

Switch Panel – 18z-1, 19c-1

C

D

Work Lights
1

  Off

2

  On (Boom)

3

  On (Boom & Cab)

Controls Isolation (2GO)
1

  Off

2

  Activate/de-activate 

  hydraulic controls

Bi-Directional and Hammer Mode Selector
1

  Bi-directional mode – Double acting 

2

  Hammer mode – Single acting

Beacon
1

  Off

2

  On (Boom)

Window Wipers
1

  Off

2

  Intermittent/ 

  continuos/washer

Fig 8

 About the Product

 Console Switches

27

9831/2900-1

27

H

Aux 2 (low flow) selection

switch

No LED illumination

J

Auto Idle on/off switch

Not used.

K

Beacon on/off switch

LED illumination: Beacon on

L

Q-Hitch sequence switch

LED illumination: Q-Hitch solenoid on

Work Lights

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on position.

Position : 1 = Off

Position : 2 = Boom and front cab work light on

Position : 3 = All work lights on

Beacon

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on and off positions.

Position : 1 = Off

Position : 2 = Beacon on

Refer to: Beacon.

 

Controls Isolation

(For: 16C-1, 18Z-1)

Controls  isolation  switch.  Two  position  momentary  rocker  switch.  Press  switch  to

activate/de-activate the control.

Position : 1 = Rest position.

Position : 2 = Momentary position (activate/de-activate hydraulic controls).

Window Wipers

(For: 16C-1)

Three position rocker switch. The switch functions operate when the ignition switch is

in the on position. The wiper will self-park when switched off.

Position : 1 = Off

Position : 2 = On

Position : 3 = Washer on (if installed)

Bi-Directional and Hammer Mode Selector

(For: 16C-1, 18Z-1)

Two position rocker switch. The switch functions operate when the ignition switch is in

the on position and auxiliary has been selected.

Position 

1

: Bi-directional mode- Double acting attachment

Position 

2

: Hammer mode- Single acting attachment

 About the Product

 Console Switches

27

9831/2900-1

27

H

Aux 2 (low flow) selection

switch

No LED illumination

J

Auto Idle on/off switch

Not used.

K

Beacon on/off switch

LED illumination: Beacon on

L

Q-Hitch sequence switch

LED illumination: Q-Hitch solenoid on

Work Lights

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on position.

Position : 1 = Off

Position : 2 = Boom and front cab work light on

Position : 3 = All work lights on

Beacon

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on and off positions.

Position : 1 = Off

Position : 2 = Beacon on

Refer to: Beacon.

 

Controls Isolation

(For: 16C-1, 18Z-1)

Controls  isolation  switch.  Two  position  momentary  rocker  switch.  Press  switch  to

activate/de-activate the control.

Position : 1 = Rest position.

Position : 2 = Momentary position (activate/de-activate hydraulic controls).

Window Wipers

(For: 16C-1)

Three position rocker switch. The switch functions operate when the ignition switch is

in the on position. The wiper will self-park when switched off.

Position : 1 = Off

Position : 2 = On

Position : 3 = Washer on (if installed)

Bi-Directional and Hammer Mode Selector

(For: 16C-1, 18Z-1)

Two position rocker switch. The switch functions operate when the ignition switch is in

the on position and auxiliary has been selected.

Position 

1

: Bi-directional mode- Double acting attachment

Position 

2

: Hammer mode- Single acting attachment

 About the Product

 Console Switches

27

9831/2900-1

27

H

Aux 2 (low flow) selection

switch

No LED illumination

J

Auto Idle on/off switch

Not used.

K

Beacon on/off switch

LED illumination: Beacon on

L

Q-Hitch sequence switch

LED illumination: Q-Hitch solenoid on

Work Lights

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on position.

Position : 1 = Off

Position : 2 = Boom and front cab work light on

Position : 3 = All work lights on

Beacon

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on and off positions.

Position : 1 = Off

Position : 2 = Beacon on

Refer to: Beacon.

 

Controls Isolation

(For: 16C-1, 18Z-1)

Controls  isolation  switch.  Two  position  momentary  rocker  switch.  Press  switch  to

activate/de-activate the control.

Position : 1 = Rest position.

Position : 2 = Momentary position (activate/de-activate hydraulic controls).

Window Wipers

(For: 16C-1)

Three position rocker switch. The switch functions operate when the ignition switch is

in the on position. The wiper will self-park when switched off.

Position : 1 = Off

Position : 2 = On

Position : 3 = Washer on (if installed)

Bi-Directional and Hammer Mode Selector

(For: 16C-1, 18Z-1)

Two position rocker switch. The switch functions operate when the ignition switch is in

the on position and auxiliary has been selected.

Position 

1

: Bi-directional mode- Double acting attachment

Position 

2

: Hammer mode- Single acting attachment

 About the Product

 Console Switches

27

9831/2900-1

27

H

Aux 2 (low flow) selection

switch

No LED illumination

J

Auto Idle on/off switch

Not used.

K

Beacon on/off switch

LED illumination: Beacon on

L

Q-Hitch sequence switch

LED illumination: Q-Hitch solenoid on

Work Lights

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on position.

Position : 1 = Off

Position : 2 = Boom and front cab work light on

Position : 3 = All work lights on

Beacon

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on and off positions.

Position : 1 = Off

Position : 2 = Beacon on

Refer to: Beacon.

 

Controls Isolation

(For: 16C-1, 18Z-1)

Controls  isolation  switch.  Two  position  momentary  rocker  switch.  Press  switch  to

activate/de-activate the control.

Position : 1 = Rest position.

Position : 2 = Momentary position (activate/de-activate hydraulic controls).

Window Wipers

(For: 16C-1)

Three position rocker switch. The switch functions operate when the ignition switch is

in the on position. The wiper will self-park when switched off.

Position : 1 = Off

Position : 2 = On

Position : 3 = Washer on (if installed)

Bi-Directional and Hammer Mode Selector

(For: 16C-1, 18Z-1)

Two position rocker switch. The switch functions operate when the ignition switch is in

the on position and auxiliary has been selected.

Position 

1

: Bi-directional mode- Double acting attachment

Position 

2

: Hammer mode- Single acting attachment

 About the Product

 Console Switches

27

9831/2900-1

27

H

Aux 2 (low flow) selection

switch

No LED illumination

J

Auto Idle on/off switch

Not used.

K

Beacon on/off switch

LED illumination: Beacon on

L

Q-Hitch sequence switch

LED illumination: Q-Hitch solenoid on

Work Lights

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on position.

Position : 1 = Off

Position : 2 = Boom and front cab work light on

Position : 3 = All work lights on

Beacon

(For: 16C-1, 18Z-1)

Two or three position rocker switch. The switch functions operate when the ignition

switch is in the on and off positions.

Position : 1 = Off

Position : 2 = Beacon on

Refer to: Beacon.

 

Controls Isolation

(For: 16C-1, 18Z-1)

Controls  isolation  switch.  Two  position  momentary  rocker  switch.  Press  switch  to

activate/de-activate the control.

Position : 1 = Rest position.

Position : 2 = Momentary position (activate/de-activate hydraulic controls).

Window Wipers

(For: 16C-1)

Three position rocker switch. The switch functions operate when the ignition switch is

in the on position. The wiper will self-park when switched off.

Position : 1 = Off

Position : 2 = On

Position : 3 = Washer on (if installed)

Bi-Directional and Hammer Mode Selector

(For: 16C-1, 18Z-1)

Two position rocker switch. The switch functions operate when the ignition switch is in

the on position and auxiliary has been selected.

Position 

1

: Bi-directional mode- Double acting attachment

Position 

2

: Hammer mode- Single acting attachment

Lifting Points

Fig 4

 Operation

 Lifting the Machine

99

9831/2900-1

99

7. Check that the lifting eye is positioned directly above the machine centre of gravity.

Figure 84.

D

A

B

B

C

F

E

G

A

Boom lift point

B

Dozer blade lift point

C

Spreader bar

D

Centre of gravity

E

Dimension= 792mm (16C-1/19C-1), 632mm

(18Z-1)

F

Dimension= 639mm (16C-1/19C-1), 659mm

(18Z-1)

G

Dimension= 533mm (16C-1/19C-1), 525mm

(18Z-1)

Description

18z-1

19c-1

19c-1 EP

A

Boom Lift Point

B

Dozer Blade Lift Point

C

Spreader Bar

D

Centre of Gravity

E

mm

632

792

792

F

mm

659

639

639

G

mm

525

533

533

*COG = Centre of Gravity

The correct lifting positions are identified on the machine by their labels:

Lifting point
Position label.

Fig 5

REFER TO OPERATORS MANUAL TRANSPORTING MACHINE

Summary of Contents for 18z-1

Page 1: ...1 Compact Excavators 18z 1 19c 1 19c 1 EP Quick Start Guide QUICKSTART JCB COM ...

Page 2: ...ly operating this product Accordingly no legal claims can be entertained on the basis of the data illustrations or descriptions in this Quick Reference Guide This machine should not be operated by any person who isn t appropriately qualified or had the appropriate training Operation of this machine without periodic maintenance could cause it to malfunction For more information please contact your ...

Page 3: ...lled machine with a tracked undercarriage 360 revolving upper structure with boom dipper bucket and slew mechanism Intended Use Machine intended to be used in normal conditions as detailed in the operators manual With bucket fitted machine work cycle consists of digging elevating slewing and discharging of materials Applications include earthmoving road construction building and construction lands...

Page 4: ...rt position A Front slew spine tie down point C Angle 35 to 46 E Angle 9 to 15 G Length 2 282mm to 1 670mm I Slew ring centre line B Rear slew spine tie down point D Angle 35 to 45 F Length 2 499mm to 1 846mm H Length 2 500mm J Tie down decal Tie Down Points Method 2 Tie Down Points Fig 2 Operation Transporting the Machine Figure 89 Method 2 F G H E E C D I J A B B A A Front slew spine tie down po...

Page 5: ...tor About the Product Console Switches 27 9831 2900 1 27 H Aux 2 low flow selection switch No LED illumination J Auto Idle on off switch Not used K Beacon on off switch LED illumination Beacon on L Q Hitch sequence switch LED illumination Q Hitch solenoid on Work Lights For 16C 1 18Z 1 Two or three position rocker switch The switch functions operate when the ignition switch is in the on position P...

Page 6: ...ers active Visual Illuminate amber when immobiliser armed M Hydraulic active Illuminate green when hydraulic services is active N Aux 1 single acting Illuminate green when single acting high flow is a Warning and Indicator Lamps Figure 51 A B C D E F G H J K L M N Table 8 A Engine pre heat Illuminate green when engine pre heater is active B Coolant temperature Illuminate red when coolant temperatu...

Page 7: ...rop too low Illuminate when the ignition switch is set to position I before starting the engine but should be extin guish when the engine starts If remains ON then stop the engine immedi ately and contact your JCB Dealer D Battery charging condi tion Audible Visual The lamp illuminate red and buzzer will sound if battery is not charging while engine is running If battery is charging the lamp and b...

Page 8: ... within two minutes the system disarms automatically To Add a New or Additional PIN Code Before you try to add a new or additional PIN code make sure that the machine is ready to start and that you have your six digit master code and your new four digit PIN code available If you are unsure of the master code or your new PIN code then do not start this procedure The keypad immobiliser can be progra...

Page 9: ...ment will move when released Stand clear and to one side when releasing the attachment 5 Apply a downward pressure on the bar to release the attachment rear pivot pin from the latch hook allowing it to swing forward as shown Attachments Quickhitch 122 9831 2900 1 122 Figure 105 A B A Pivot pin B Jaw Maintenance Check the operation of the Quickhitch daily Examine the Quickhitch daily for broken or ...

Page 10: ... displayed Turn ignition to position 1 A so that the instrument panel and switches become active Change Aux mode between Aux1 A and Aux 2 B using mode select switch on the right hand console Press 2 GO button A to activate hydraulics Instrument panel will illuminate B when active Operate the roller switch fully in both directions to release stored pressure Right hand A for Aux 1 and left hand B fo...

Page 11: ...wered 2 Use the ignition key to unlock the cover 3 To release the latch pull the handle Figure 114 B C A A Lock B Engine compartment cover C Handle Mai Electric 182 9831 2900 1 Figure 133 A A B A Knob B Cover Relays Replace Refer to Relays 1 Make the machine safe Refer to Maintenance Position Excavator Arm Lowered 2 There are relays behind a panel under the seat Refer to Figure 134 2 1 Loosen the ...

Page 12: ... Ring Bearing As required JCB HP Grease 4003 2017 0 4kg Slew Ring Gear Teeth As required JCB Special Slew Pinion Grease 4003 1619 0 4kg All Other Grease As required JCB MPL EP Grease 4003 1501 0 4kg JCB part numbers are liable to change and may also vary by region For the latest information always check with your dealer distributor Access Covers Fluid Levels and Fill Fig 27 Fig 28 A Hydraulic comp...

Page 13: ...t overload warning indicator when not object handling press button C on the switch panel refer to page 9 500hrs Greasing Does it matter if greased every day No there is no impact on life of the pivot pins or bushes Machine Attachments Description Weight kg Intended Use Hydraulic Requirements Mechanical Quickhitch 13 7 Quick change of attachments None Hydraulic Quickhitch 22 Quick change of attachm...

Page 14: ...seals stopping dirt entering the bush but allowing old grease out when greasing How do I switch from ISO to SAE control patterns The control pattern change over switch is located under the operator station station Position 1 SAE Position 2 ISO Always refer to the in cab display for confirmation of control pattern selection How do I activate continuous auxiliary flow 19c 1 EP only To activate const...

Page 15: ...y and may vary dependant upon the exact specification of the machine They should not therefore be relied upon in relation to suitability for a particular application Guidance and advice should always be sought from your JCB Dealer JCB reserves the right to change specifications without notice Illustrations and specifications shown may include optional equipment and accessories JCB Sales Limited Ro...