JBL VerTec DP Series Product User Manual Download Page 28

8

V

ER

T

EC

 User’s Guide

The V

ER

T

EC

 DP Series has optional advanced network control capabilities with the DPAN, DPCN or DPDA 

input modules.  V

ER

T

EC

 DP Series loudspeaker systems utilize Harman Professional’s HiQnet™ protocol 

to enable a complete configuration, control, and monitoring solution.  HiQnet protocol provides remote 
access to loudspeaker preset files in the JBL DrivePack® input modules making system setup easy yet 
powerful, via the DrivePack Software Device Control Panel with its intuitive, user-friendly graphical interface.  
HiQnet System Architect™ provides complete software control of not only your JBL DrivePack-equipped 
loudspeakers, but also other HiQnet-compatible audio components within the total system. 

It is recommended to visit www.harman.com for the most up to date version of HiQnet System Architect.

QUICK-START CONFIGURATION GUIDE

For JBL DrivePack-equipped loudspeaker Systems using System Architect software                      

INTRODUCTION:

This guide applies to all JBL loudspeaker models powered by DrivePack DP1, DP or DP amplifier 
assemblies which incorporate DPAN, DPCN or DPDA input modules.  
Each loudspeaker must be connected to a 100BaseT Ethernet switch using a standard CAT-5 cable. 
Loudspeakers with DPDA input modules could alternatively use one CAT-5-to-switch connection per cluster. 
The control computer which will run System Architect must also be connected by a 100BaseT connection to 
a switch on the same physical network.
If managed Ethernet switches are a part of the network, additional knowledge of TCP/IP protocols and 
Ethernet-switch manufacturer-specific configurations may be required. This is beyond the scope of this 
document. It is assumed that unmanaged switches are used in the networking examples discussed below.
Special requirements exist for CobraNet™ - compliant products using the DPCN input module. This is 
addressed in Appendix A.
A Glossary of networking terminology used is provided at the end of this document.

AS-SHIPPED ETHERNET CONFIGURATION:

Each loudspeaker product is shipped from the JBL factory with the following configuration:
   - DHCP is enabled. (See glossary for details)
   - Auto IP address negotiation is enabled (See glossary for details)
   - Auto HiQnet device setting is enabled. (See glossary for details)
   - The default IP address for all products shipped is 169.5.17.1 with subnet mask 55.55.0.0

QUICK-START: CONFIGURING YOUR PC WITH SYSTEM ARCHITECT™ SOFTWARE: 

1)   Install System Architect software on the Microsoft Windows 000 or XP-equipped computer that will 
control/monitor the HiQnet™ - compliant products.

)   Note that System Architect will only display graphics correctly when the Windows PC display is set to 
standard, small font size. If Windows is set to “large” fonts, then the displays within System Architect may 
become unreadable. To correct this problem change Windows to the standard font size. (See Appendix B for 
details) 

)   Note that System Architect will only display graphics correctly when the Windows PC. Regional and 
Language settings are set to standard US English language. If Windows is set to any language other than 
US English, objects in custom control panels will not display or function properly.  To correct this problem 
change Windows to the standard font size. 

(See Appendix C for details) 

)   If you are using a CobraNet™ - compatible product see Appendix A for special instructions now before 
proceeding further.

SECTION 8 : 

SYSTEM ARCHITECT SOFTWARE

www.audiovias.com

Summary of Contents for VerTec DP Series

Page 1: ...Product User s Guide Compact Powered Line Array Systems VT4887ADP VT4887ADP DA VT4887ADP AN VT4887ADP CN VT4881ADP VT4881ADP DA VT4881ADP AN VT4881ADP CN www audiovias com...

Page 2: ...VERTEC User s Guide www audiovias com...

Page 3: ...ces Section 7 JBL DrivePack Technology Page 15 AC Power Module Electrical Information Input Modules DPIP DPDA DPAN DPCN Protective Jackets installation Section 8 HiQnet System Architect Software Confi...

Page 4: ...he apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a c...

Page 5: ...he user to important operating or maintenance instructions FCC COMPLIANCE NOTICE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device m...

Page 6: ...essional Use Part 2 Immunity EN 61000 4 2 1995 A1 1999 A2 2001 Electrostatic Discharge Immunity Environment E2 criteria B 4 kV Contact 8 kV Air discharge EN 61000 4 3 2003 Radiated Radio frequency Ele...

Page 7: ...such as polished wood or linoleum a single speaker may move due to its acoustical energy output Precautions should be taken to assure that the speaker does not fall off a stage or scaffold platform o...

Page 8: ...ncy Class I power amplifier circuitry Loudspeaker components include patented JBL Differential Drive woofers This guide covers the following models VT4881ADP 1x18 subwoofer system VT4881ADP DA DPDA ne...

Page 9: ...ecision bandpass filters limiting pre equalization filters and automatic self test functions System Management DSP based limiters for mechanical and thermal protection Signal Input F XLR Active 20K Oh...

Page 10: ...hnology features a unique design with heat sinks integrated into the cast aluminum frame for a highly improved performance to weight ratio The dual voice coil design places the neodymium magnets insid...

Page 11: ...wood enclosures do not paint the JBL DrivePack 1 Prepare the enclosure surface by cleaning and wiping off dust and film with a damp cloth It may be necessary to use a mild household cleaner to remove...

Page 12: ...merica and may not directly apply to other countries because of differing material dimensions specifications and or local regulations Users in other countries should consult with appropriate engineeri...

Page 13: ...he Professional Engineer for design purposes Uniform Building Code as applicable Municipal Building Code as applicable Seismic Code as applicable Installation of hardware and method of attachment must...

Page 14: ...hrough the U S A For a location near you visit them online www mcmastercarr com Safe Rigging The JBL VERTEC DP Series arrayable loudspeakers are equipped with integral suspension hardware and should o...

Page 15: ...ness of wood or composite material and with load impedances of 4 Ohms 8 Ohms for low and mid frequency channels and 8 or 16 Ohms for the high frequency channel OPERATING INSTRUCTIONS All that is requi...

Page 16: ...TE Tighten set screws to 2 5Nm 1 8lb ft torque to prevent opening by hand USER FABRICATED AC POWER DISTRIBUTION System owners may choose to fabricate or purchase a custom AC Power cable infrastructure...

Page 17: ...Wiring 16 AWG 1 5 mm2 Inlet Connector Rating 5A 3 2A Outlet Connector Rating 7A 8 8A Line Voltage Selection The DrivePack features an international Auto Sensing power supply and will automatically se...

Page 18: ...cient cooling it is a good practice to assure open space around the DrivePack units Operating Temperature The system will remain touchable during quiescent operation and will not provide a burn hazard...

Page 19: ...y fault condition 4 THERMAL PROTECTION a Orange LED illuminates during thermal limiting ai PULSING indicates first stage of thermal limiting amplifier output level is reduced to prevent overheating ai...

Page 20: ...esets can be stored internally In addition Master Control Panels and Master Monitor Panels within System Architect software allow for convenient grouping of control and monitoring functions for multip...

Page 21: ...anually determine the position of the speakers within the array via the rotary dial Note Array ID Loudspeaker ID Examples Example A 00 00 would be complete auto ID mode Example B 01 01 would be Array...

Page 22: ...and slopes are model dependent Internal Controls Input Sensitivity 2 Position Switch Located on the back side of the front panel full output is achieved by selecting either 4 dBu in one position or 2...

Page 23: ...tage produces outward cone motion of L F Transducers 9 AUDIO OUT a M XLR Passive Audio Pass through b Pin 2 Hot Positive voltage produces outward cone motion of L F Transducers 10 HiQnet 100MB NETWORK...

Page 24: ...are model dependent 2 INTERNAL CONTROLS Internal 4 dBu or 20 dBu sensitivity select switch See NOTE on DPAN for details INDICATORS 2 ENABLE ALT PRESET a Orange LED illuminates when the function is ena...

Page 25: ...raNet digital audio on the same CAT5 cable Should the Primary connection 10a lose Link activity with the network the DPCN will automatically switch to the Secondary connection 10b to ensure uninterrup...

Page 26: ...protect cables and connectors Protective Jacket Installation Complies with IEC 60529 IPX 3 not evaluated for outdoor use 1 Remove two protective jackets from the protective jacket kit To install open...

Page 27: ...round the riser ring as shown 6 Zip up the Velcro strip and pull the draw cord closed as required as shown in Figure 5 The protective jacket should now be securely fastened all the way around the rise...

Page 28: ...red This is beyond the scope of this document It is assumed that unmanaged switches are used in the networking examples discussed below Special requirements exist for CobraNet compliant products using...

Page 29: ...to your JBL DrivePack and wait for it to boot up With DHCP enabled the DrivePack and your computer should both automatically negotiate an IP Address Step 3 Launch System Architect The DrivePack system...

Page 30: ...ouble click on the icon and the network will activate Step 2 On the ribbon toolbar of System Architect click on Tools and then select Readdress Devices The wizard will open up Click on Next to go to t...

Page 31: ...a single component It will highlight click on the CONFIGURE button located on the bottom of the window Step 5 System Architect will have detected the device automatically assigned a HiQnet address an...

Page 32: ...32 VERTEC User s Guide www audiovias com...

Page 33: ...ers For info go to http www harmanpro com hiqnet HiQnet Address The HiQnet address is a unique number that allows System Architect software the PC in use and the connected devices to keep track of eac...

Page 34: ...quality real time audio delivery Audio Specs All CobraNet devices operate at a fixed sample rate of 48kHz The audio data may be transmitted at 16 20 or 24 bit data as desired For reliable operation e...

Page 35: ...on the entire network More Bundles may be allowed if they are loaded with less than the full eight audio channels There is no limit to the number of active receivers on a repeater network Generally a...

Page 36: ...Windows control panel 2 Double click on the Display panel the Display Properties panel will open 3 Next click on the Appearance tab 4 Go to the Font size drop down menu and select Normal 5 Click on t...

Page 37: ...nal and Language Options to U S United States English 1 Open the Windows control panel 2 Double click on Regional and Language Options icon Regional Options panel will open 3 Click on the Languages ta...

Page 38: ...Services and Input Languages panel will open 6 Go to the Default input language drop down menu and select English United States U S Click on the OK button to close the Text Services and Input Languag...

Page 39: ...the original shipping cartons because a charge will be made if replacement cartons are requested Payment of shipping charges is discussed in the next section of this warranty How to Obtain Warranty P...

Page 40: ...BLPRO 800 852 5776 www jblproservice com On the World Wide Web www jblpro com Outside the USA Contact the JBL Professional Distributor in your area A complete list of JBL Professional international di...

Page 41: ...41 JBL Professional www audiovias com...

Page 42: ...Part Number 362870 002 VTDP C PROD GUIDE 0710 8500 Balboa Boulevard Northridge CA 91329 USA Visit us online at www jblpro com www audiovias com...

Reviews: