17
Appendex A
Diagram D details the connections using single conductor shielded cable with a Tip/Ring/Sleeve plug for the 6328P input. Single con-
ductor cable should be used as a last resort as it provides the greatest likelihood of problems. The "HOT" (+) signal should be connect-
ed to the tip of the Tip/Ring/Sleeve plug. The GROUND should be attached to the Ring of the Tip/Ring/Sleeve plug at the 6328P input.
Diagram E details the connections using unbalanced cable and Tip/Sleeve connections to the 1/4" input. In this mode, the Ring and
Sleeve of the input are shorted by the plug automatically.
Tip
Sleeve
(Tip)
(Ring)
(Sleeve)
Pin 2
Pin 3
Pin 1
+
+
-
LSR Input
Unbalanced Source
Tip
Sleeve
Tip
Ring
Sleeve
+
+
-
LSR T/R/S Input
Unbalanced Source
Unbalanced Tip/Sleeve Connectors
short the Ring and Sleeve Automatically
Diagram D
Diagram E