MASTER SECTION
AUX OUTPUT MASTERS
Each of the three auxiliary outputs (
AUX1
~
AUX3
) has a mas-
ter level control which sets the output level of the combined
auxiliary signals from the channels, and an associated
AFL
(After Fader Listen) switch. Just as a channel’s
SOLO
switch
allows pre-fade listening, you can monitor each auxiliary output
after the level control by pressing the
AFL
switch to determine
what level is leaving the output connector. This routes the aux-
iliary output signal to the
MONITOR
or
PHONES
circuits,
replacing any existing signal which is selected. The console
METERS
will also switch from the selected source to display the
PFL/AFL signal and the
PFL/AFL
LED lights to warn that a
PFL
or
AFL
switch is pressed. When you release the switch the
MONITOR
returns back to the previous source.
LEX FX MASTER
The
LEX FX
master control sets the overall level of the effects
sends from the channels before the input of the Lexicon
Digital Effects Processor. An associated
AFL
switch allows the
signal to be monitored in the same way as the auxiliary masters
(see above callout).
NOTE: When the
LEX FX AFL
switch is pressed, the meters become the
Lexicon Input level indicators.
SUB TO MIX
The submaster mix may be used to provide alternative outputs
from the mixer or, by pressing
SUB TO MIX
, the SUB L and R
master faders may be used as audio subgroups.When
SUB TO
MIX
is selected, the combined level of input channels are
added to the main mix under the control of a pair of faders.
L SUB R (Master) Faders
The
L SUB R
(master) faders set the final level of the submaster
L and R outputs. Assuming input
SENS
settings have been
correctly set, the
L SUB R
(master) faders should be set close to
the ‘
0
’ mark to provide maximum travel on the faders for
smoothest control.
4
3
2
1
14
M I X E R O P E R A T I O N
L SUB R
L MIX R
1
7
6
2
4
3
5
19
13
12
21
20
8
9
10
15
16
17
18