Settings
Program Settings
Edit Program
Edit Program 8
1 Temp unit
Celsius
2
Maximum temp 450
0
C
3
Minimum temp T OFF*
4 Fix temp 400
0
C
5 Temp Adjust 0
0
C
6 Max air 100%
7 Min air 10%
8 Fix air 40%
9 Time to stop 120 sec
10 Beep ON
11 Pop up ON
12 Change PIN
1
Programs
2 Edit program
3
Copy program
4 Delete program
Back
Select
Program
Step
4
Time
20
Temp 450
Air
100
º
C
º
C
8
Exit
Counters
1 Station ON hours
0
2 Works hours 0
3
Works cycles 0
Back
14
15
* Selecting Minimum Temp to
“T OFF” allows for blowing at
ambient temperature.
Menu screen
Original PIN: 0105
Only perform this operation when the element is cold and the unit is disconnected from the mains.
1.
Loosen the screw.
2.
Pull the heating element away from the handle.
3.
Connect the new heating element, ensuring its pushed all the way in.
4.
Tighten the screw.
JT-TA Replacing the Heating Element
Heating Hose Set
Ref. JT-T1A (100V / 120V)
JT-T2A (230V)
Heating Element
Ref. 0014107 (230V)
0014105 (100V / 120V)
Handle
Ref. 0009829
1.
Ensure that the tool is turned off.
2.
Use a spanner to unscrew the connecting nut.
3.
The tube end of the new heater must be inserted
so that the longitudinal rib fits into the groove.
5.
Follow the same steps conversely.
JT-TA Changing the Heater Hose Set
www.jbctools.com