background image

30

31

Clean periodically

Maintenance

1.

 Connect the tool to the station port by means of the Converter.

2.

 Connect your Robot system to the Robot connector (RJ12) of the station. 

  DB9-RJ12 Adapater available only if necessary (Ref: 0013772).

3.

 Enable the Robot option in the station settings and the notification will be displayed:

4. 

Set your Robot’s commands according to the Robot Communication Protocol, available on the 

  website 

www.jbctools.com/jbcsoftware-menu-115.html

.

Manage and monitor the station using a Robotic system. 

Working with Robots

Control 
Unit

Robot

Update the station software

1. 

Download the JBC Update File from 

www.jbctools.com/software.html 

and save 

it on a USB flash drive. Preferably one with 
no other files.

JBC  

Update File

Before carrying out maintenance or storage, always allow the equipment to cool. 

- Clean the station screen with a glass cleaner 

or a damp cloth.

1.

 Pull off the fuse holder and remove the  

  fuse. If necessary use a tool to lever it off.

2. 

Press the new fuse into the fuse holder  

  and replace it in the station.

- Use a damp cloth to clean the casing and 

the tool. Alcohol can only be used to clean 
the metal parts.

- Periodically check that the metal parts of 

the tool and stand are clean so that the 
station can detect the tool status.

Fuse holder

Fuse holder

- Maintain tip surface clean and tinned prior 

to storage in order to avoid tip oxidation. 
Rusty and dirty surfaces reduce heat 
transfer to the solder joint.

- Periodically check all cables and tubes.

Converter

Ref. 0002747

2. 

Insert the USB flash drive to the station.

The icon         is diplayed while updating.

Fuse

RS-232

connection

   

 
- Replace a blown fuse as follows:

- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.

www.jbctools.com

Summary of Contents for RMVE-B

Page 1: ...Premium Complete Rework station with Pneumatic Pump Ref RMVE B Espa ol 35 English 3 Page www jbctools com...

Page 2: ...nit MVE Module Features 16 Stands Tip Cleaner 18 T245 Changing Cartridges 20 DR560 Changing Tips 21 DR560 Changing the Heating Element 22 DR560 Tin Deposit Cleaning 23 DR560 Tip Care 24 Desoldering Pr...

Page 3: ...E Control Unit 1 unit Ref JTE 1C 120V JTE 2C 230V JTE 9C 100V Tip Cleaner 1 unit Ref CL9885 JT Accessory set Ref 0012332 Sponge 1 unit Ref S0354 Metal Brush 1 unit Ref CL6217 Cartridges 2 units Ref C2...

Page 4: ...005 Ref C560013 Ref C560004 Manual 1 unit Ref 0016198 Premium Complete Rework station with Pneumatic Pump Ref RMVE B Stand Cable 2 units Ref 0011283 Power cords For DDE 1 unit Ref 0013671 100 120V 001...

Page 5: ...Precision Heater hose set Ref TE TB Power Socket Fuse Equipotential connection To Pedal Ref P 005 Press the pedal to start hot air or release to stop In case of loosely fitting nozzle Ref Shape Size...

Page 6: ...d using the extractors Protectors Extractors 1 2 3 4 Protectors Ref AxB mm Ref AxB mm P3353 4 3 x 3 48 P2230 15 x 15 P3786 5 2 x 5 2 60 P4010 17 x 17 P3352 5 2 x 7 5 P4005 18 x 29 P3355 5 2 x 9 5 P403...

Page 7: ...ng time Program mode Program Options Edit Program This option allows you to edit or create a program First you must select the program to edit and then modify the points that make up the program Each...

Page 8: ...Temp to T OFF allows for blowing at ambient temperature Menu screen Original PIN 0105 Only perform this operation when the element is cold and the unit is disconnected from the mains 1 Loosen the scr...

Page 9: ...potential connection Power Socket Desoldering Iron Ref DR560 A Cartridge Ref C245903 Ref C245906 Tip Ref C560004 Ref C560005 Ref C560013 Pneumatic Desoldering Module Ref MVE A 16 17 Stand Ref DR SD St...

Page 10: ...ve cleaning method It leaves a small layer of solder on the tip to prevent oxidation between cleaning and rewetting It prevents splashing of solder particles Also used for sponge or brushes for Sponge...

Page 11: ...vel Special models Save time and change cartridges safely without switching the station off DR560 Changing Tips This operation should be done while the tip is hot not below 250 C so that any tin left...

Page 12: ...the cartridge by lining it up to the mark DR560 Tin Deposit Cleaning 1 Removing the lid 3 Inserting the deposit Check filter Lid Check internal joint 2 Cleaning The filter and internal joint must be...

Page 13: ...remove the solder 3 Aspirating 1 Placing 2 Rotating The intake tube should be periodically cleaned by the largest rod DR560 Tip Care Important DO NOT press the vacuum pump button while tinning the de...

Page 14: ...om 0 to 9 min or no Sleep Set Hibernation delay from 0 to 60 min or no hibernation Tools Menu Tools Menu Long time in the stand Set temperature limits Select temperature levels 350 C Port 2 Power 45 T...

Page 15: ...port graphic Soldering Net Remotely manage and monitor as many stations as your PC can handle Functions Set all the station parameters from your PC Organize groups of stations and set all their param...

Page 16: ...equipment to cool Clean the station screen with a glass cleaner or a damp cloth 1 Pull off the fuse holder and remove the fuse If necessary use a tool to lever it off 2 Press the new fuse into the fus...

Page 17: ...iance and understand the hazards involved Children must not play with the appliance Maintenance must not be carried out by children unless supervised It is imperative to follow safety guidelines to pr...

Page 18: ...MVE m dulo Caracter sticas 48 Soportes y limpiador de puntas 50 T245 Cambiar Cartuchos 52 DR560 Cambiar Puntas 53 DR560 Cambiar elemento calefactor 54 DR560 Limpiar dep sito de esta o 55 DR560 Manteni...

Page 19: ...ion Tube Tubo de succi n Ref 0932330 Suction Cups Ventosas Ref 0930110 10 0934050 x3 4 7 0934070 x1 Extractors Extractores Ref E2184 E2064 E2052 Protectors Protectores Ref P2220 P2230 P2235 P4000 P401...

Page 20: ...unidad Ref 0965970 Long Tip Cleaning set Juego de limpieza de puntas largo 1 ud Ref 0965760 Tips Puntas 3 unidades Ref C560005 x1 Ref C560013 x1 Ref C560004 x1 Tin deposit Dep sito de esta o 1 u Ref 0...

Page 21: ...a conectable Precision Heater hose set Conjunto calefactor de precisi n Ref TE TB Entrada de red Fusible Conexi n equipotencial Al Pedal Ref P 005 Con el pedal pulsado se emite aire caliente Para una...

Page 22: ...extractores Recomendamos usar protector tr pode 1 2 3 4 Protectores Ref AxB mm Ref AxB mm P3353 4 3 x 3 48 P2230 15 x 15 P3786 5 2 x 5 2 60 P4010 17 x 17 P3352 5 2 x 7 5 P4005 18 x 29 P3355 5 2 x 9 5...

Page 23: ...opci n le permite crear o editar un programa Seleccione un n mero de programa a editar y modifique los puntos en funci n de sus necesidades de trabajo Cada programa se compone de 9 puntos y cada punt...

Page 24: ...ra permite la emisi n de aire ambiente Pantallas de Men PIN original 0105 Heating Hose Set Conjunto calefactor Ref JT T1A 100V 120V JT T2A 230V Heating Element Elemento calefactor Ref 0014107 230V 001...

Page 25: ...e Mango aislante t rmico suave Ref T245 C Conector RJ12 para Robot Conector USB B Conexi n equipotencial Toma de correinte Desoldering Iron Desoldador Ref DR560 A Cartridge Cartucho Ref C245903 Ref C2...

Page 26: ...sponja Ref S0354 No es necesario sujetar la base El m todo de limpieza m s eficaz y menos da ino Mantenga la esponja h meda con agua destilada as evitar el desgaste de la punta Recept culo resistente...

Page 27: ...jbctools com Redondo Cincel Redondo curvado Bisel Modelos especiales Ahorre tiempo cambiando los cartuchos de forma r pida y segura sin apagar la estaci n DR560 Cambiar puntas Esta operaci n debe rea...

Page 28: ...ho aline ndolo con la marca DR560 Limpieza del dep sito de esta o 1 Retirar la tapa 3 Insertar el dep sito Compruebe el filtro Tapa Compruebe la junta interna 2 Limpiar El filtro y la junta interna de...

Page 29: ...n esta o nuevo y repita el proceso de desoldadura Cuando la soldadura se liq e gire la punta con suavidad para que el terminal del componente se suelte Pulse el bot n de la bomba de succi n hasta reti...

Page 30: ...eratura predefinida Tras largos periodos de inactividad predefinido a 30min se corta el suministro de energ a y la punta se enfr a hasta temperatura ambiente Men Tools Configure la temperatura de Slee...

Page 31: ...otro puerto Red de soldadura Gestione y monitorice tantas estaciones como soporte su PC Funciones Configure todos los par metros de la estaci n desde su PC Organice grupos de estaciones y configure to...

Page 32: ...o o almacenar desconecte el equipo y d jelo enfriar 1 Tire del portafusible para retirar el fusible Si lo precisa utilice una peque a palanca 2 Sustituya el fusible y coloque de nuevo el portafusibles...

Page 33: ...aratodeunamanerasegurayentiendanlosriesgosqueimplica Losni os no deben jugar con el aparato Los ni os no deber n realizar tareas de mantenimiento sin supervisi n Es necesario cumplir estas normas de s...

Page 34: ...66 67 Exploded View Despiece www jbctools com...

Page 35: ...pment at the end of their life must be collected and returned to an authorized recycling facility Garant a Esta garant a de 2 a os cubre este equipo contra cualquier defecto de fabricaci n incluyendo...

Reviews: