background image

Main menu

1        Reset settings
2       Station Settings

3

       Profile Settings

4       Counters

5        Program version

Exit

Settings

Profile Settings

Edit Profile

Edit Profile 8

1     Temp unit

                

 Celsius

  

 Maximum temp     450

0

C

3

    Minimum temp         T OFF*

4   Fix temp                    400

0

C

5    Max air                        100%
6    Min air                             10%
7    Fix air                             40%
8    Time to stop           120 sec
9    Beep                                     ON
10  Pop up                                 ON
11   Change PIN

1       

 

Profiles

2       Edit Profile

3

       Copy profile

Back

Select

Profile

Step 

4

Time 

20

Temp  450
Air 

100

º

C

º

C

8

Exit

Exit

Counters

1       Station ON hours  

      

            0

2      Works  hours                                0

3

     Works cycles                      0

Back

7

* Selecting Minimum Temp to 
“T OFF” allows for blowing at 
ambient temperature.

Menu Screen

Original PIN: 0105

www.jbctools.com

Summary of Contents for JTE-1B

Page 1: ...www jbctools com Hot Air Station Ref JT B www jbctools com...

Page 2: ...Unit Ref JTE 1B JTE 2B JTE 9B Extractor stand Ref 0008752 Suction Tube Ref 0932330 Suction Cups Ref 0930110 10 0934050 x3 4 7 0934070 x1 Power Cord Ref 0009417 100V 120V 0009401 230V Extractors Ref E2...

Page 3: ...Create graphs Manage parameters via PC Connectable tools JT T2A JT T1A Heater hose set TE TB Precision Heater hose set Heating element Hot Air switch ON OFF Suction Tube Main switch Heater inlet Vacu...

Page 4: ...n the nozzle tab with a screwdriver or flat nosed pliers Ref Shape Size JN2020 Straight 8mm JN8417 Straight 10mm JN2015 Bent 4mm JN2012 Bent 6mm JN6633 Bent 8mm JN7637 Flat 10 x 2mm JN7638 Flat 20 x 2...

Page 5: ...P3784 8 2 x 8 2 P4085 31 5 x 31 5 P4035 9 x 13 P2672 33 x 46 P4040 9 5 x 19 P4002 50 x 50 P4080 9 5 x 21 P3357 52 5 x 14 32 P2220 10 x 10 P4045 10 5 x 21 P4090 11 x 16 24 P2235 12 x 17 P1249 12 x 23...

Page 6: ...Confirm Selection Access Menu pess key 2 seconds Selected temperature Current temperature Instant power supplied to heater Selected profile Current temperature Selected flow Graph of selected profile...

Page 7: ...Fix temp 4000 C 5 Max air 100 6 Min air 10 7 Fix air 40 8 Time to stop 120 sec 9 Beep ON 10 Pop up ON 11 Change PIN 1 Profiles 2 Edit Profile 3 Copy profile Back Select Profile Step 4 Time 20 Temp 45...

Page 8: ...y selecting in the time parameter It should be taken into account that the regulation range permitted by the station is between 150 C and 450 C whereby it is not possible to create temperature ramps b...

Page 9: ...heating element ensuring its seated all the way in 4 Replace screw 3 Pull back the connecting nut 4 Tube end must be inserted positioned so that the longitudinal rib can fit into the groove 5 Follow...

Page 10: ...to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes connections Replace the fuse if it is blown according to the following...

Page 11: ...lation grills Heat can cause inflamable products to ignite even when out of sight Use a non residue classified flux and avoid contact with skin or eyes to prevent irritation Be careful with the fumes...

Page 12: ...ace station PC Complies with CE standards ESD protected housing skin effect Technical Specifications Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects including th...

Reviews: